Baumer OM30 Instrukcja obsługi - Strona 33

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przyrządy pomiarowe Baumer OM30. Baumer OM30 48 stron. Laser distance sensors

Baumer OM30 Instrukcja obsługi
Baumer
Window mode (switching output behavior)
Positive hysteresis:
Level
Ill. 18: Behavior of the switching output in window mode (positive hysteresis)
Negative hysteresis:
Level
Ill. 19: Behavior of the switching output in window mode (negative hysteresis)
IO-Link parameter: Hysteresis
Parameter name
Hysteresis.SSC1 Width
OM20/OM30 | V1
Window
Window
Values
Description
-
Enter the hysteresis as a positive or negative nu-
merical value (in mm).
Operating Manual
Functions
Hysteresis
Switching point P1
Switching point P2
Hysteresis
High
Active high level
Low
Switching point P1
Hysteresis
Hysteresis
Switching point P2
High
Active high level
Low
|
8
33