Line 38
Line 39
Line 40
Switching back ➜ Hold down the key
through the program lines
Switching off the ➜ Press the
programming mode ● The device is now on the operating mode again.
Reprogramming the device ➜ Press the keys
with the default setting
Example 1 decimal place
Decimal point for F3 (see line 21)
with measurement function
0, 1 or 2
0 * no decimal point
1
0.0
2
0.00
3
0.000
Assignment of the basic display (reset after 15 s)
0 * No switchover to the basic display
1
F1
2
F2
3
F3
Code setting
0 * 0 No code
1...9999
The dotted line represents the end of the third programming field.
key
same time.
● All values which have already been programmed are returned to
the default settings. Display shows for a short time „ClrPro" .
5.1

Measuring speed and rpm

When using the TA 201 for measurement of revolutions per minu-
te, the time unit for F1 (tachometer 1) is set for rpm. in line 30, and
for F2 (tachometer 2) in line 31. The number of pulses per revolution
(scale) is specified in line 25 for F1, in line 26 for F2.
Decimal places
If you wish the display to include decimal places, this must be taken
into account when setting the measurement and decimal point as
follows:
= scale x 0.1
2 decimal place
= scale x 0.01
3 decimal place
= scale x 0.001
www.baumerivo.com
with measurement function
3, 4, 5 or 6
59.59.99 min
99.59.59 h
and press the key
and
and switch on the device at the
TA201
again.
decimal point 0.0
decimal point 0.00
decimal point 0.000