7.
Position the Filter and Assemble the Filter for each
Housing – see figure 5a to 5d
7.1
Mark the required head position for fixing using the paper template supplied
Figure 5a
7.2
Grip the grey filter caps (E) and twist to the 'unlock' position
Pull down to disengage the filter caps (E) from the heads (C) and put the
7.3
filter caps (E) and filter bodies (F) to one side
7.4
Remove all packaging and fix the mounting plate (B) and filter heads (C) to
the unit or wall with the 6 screws (D) provided
Figure 5b
7.5
Unscrew the filter bodies (F) from the filter caps (E), open the filters and
discard the protective bags from the pre filter (G) of the left hand housing
and the ceramic filter (H) of the right hand housing
Figure 5c
Screw the threaded pre filter (G) into the grey filter cap (E) of the left hand
7.6
housing until washer resistance is felt, repeat for the ceramic filter (H) for
the right hand housing - do not over tighten
Screw the white filter bodies (F) into the grey filter caps (E) until a positive
7.7
stop is felt
Figure 5d
Align the arrow on the grey filter cap (E) of the assembled pre filter to the
7.8
unlock position on the left hand filter head (C) and push the assembled
filter firmly into the head until the clicks into position. Repeat this for the
assembled ceramic filter into the right hand filter head.
7.9
Twist the grey filter cap (E) of the assembled pre filter until the arrow is
aligned with the locked position on the left hand filter head (C). Check that
the arrows align to ensure that the filter is fully locked. Repeat this for the
assembled ceramic filter into the right hand filter head
Note: it is important that pre filter and ceramic filter are fitted in
the correct locations - See figure 6
Figure 1/6
8.
Install the pipe work and non return valve – see
figure 6
8.1
Measure and cut the tubing (I) to the length required to connect the inlet
port of left hand filter head (C) to the Tee adaptor (K). The length of the
tubing must be a minimum of 200 mm (8"). Take the cut length of tubing
and cut it in half
8.2
Fit one end of each tube into the non return valve (J)
Figure 6
Q. 3 way Mixer Tap
Prefilter
I
O
N
I
I
P
K
I
J
Mains cold
M
water supply
Figure 5a
Figure 5b
C
E
F
Figure 5c
Figure 5d
E
G/H
F
Figure 7
Ceramic Filter
Direction of flow
Incoming mains
water
8.3
Connect the non return valve (J) to the inlet port of the left hand filter head
(C) and the tee adaptor (K) with the tubing (I). Ensure that the flow arrow
on the non return valve (J) is pointing in the direction of the filter head (C)
8.4
Measure and cut the tubing (I) to the length required to connect the
outlet port of the right hand filter head (C) to the 7/16" adaptor (N) on the
E
filtered water hose on the mixer tap. Connect the tubing to the filter head
outlet port and mixer tap
Bag
8.5
Check that the arrows on non return valve (J) and the ports of the left
and right hand filter heads (C) are pointing in the correct direction of flow
G/H
towards the mixer tap – see page 1 and figure 7
9.
Check the system for leaks
For guidance on identification of system components see page 1 and
figure 1
9.1
With the mixer tap filtered and hot/cold water taps open, slowly turn on the
F
mains water to allow the system to fill gradually until all of the trapped air
has been expelled from the system
9.2
Check for leaks around the mains supply pipes and adaptors, non return
valve, filter head inlet and outlet ports and filtered water adaptor. Also
check for leaks between the filter head, cap and filter body
9.3
If there are leaks from the adaptors, non return valve or filter head
ports:
C
•
Turn off the mains water supply
•
Open the mixer tap filtered and hot/cold water taps to release pressure
from the system
•
Press in on the collar around the tubing where it enters the adaptor, see
E
figure 8
•
Pull the tubing to release it from the adaptor
•
Check to make sure that the tubing is cut square and that that it is not
scratch ed or crimped
F
•
If the tubing is unevenly cut or scratched, cut off the damaged section
squarely and re install the tubing
•
With the mixer tap filtered and hot/cold water taps open, slowly turn on the
mains water to allow the system to fill gradually
•
Check the system for leaks
Figure 8
Push collar
Pull
Tubing
Collar
Adaptor
9.4
If there are leaks from the filter head:
•
Turn off the mains water supply
To mixer tap
•
Open the mixer tap filtered and hot/cold water taps to release pressure
from the system
•
Remove the filter assembly, as described in section 7.2 – 7.3/figure 5a
•
Check the O-rings around the top of the grey filter cap (E), ensure that
they are in place and free from dirt and particles, see figure 9
•
Re-fit the filter assembly, as described in section 7.8 – 7.9/figure 5d
•
With the mixer tap filtered and hot/cold water taps open, slowly turn on the
mains water to allow the system to fill gradually
•
Check the system for leaks
9.5
If there are leaks from the filter cap and filter body:
•
Turn off the mains water supply
•
Open the mixer tap filtered and hot/cold water taps to release pressure
from the system
•
Remove the filter assembly, as described in section 7.2 – 7.3/figure 5a
•
Unscrew the filter body (F) from the filter cap (E)
•
Check the O-ring around the top of the filter body, ensure it is in place and
free from dirt and particles
•
Remove the filter element by unscrewing from the filter cap and place to
one side ensuring that the open ended plastic mount is kept clean to avoid
contamination
•
Check the inside of the filter cap on the surface where the body O-ring
seals, ensure it is free from dirt and particles, see figure 9
•
Re fit the threaded filter element and reassemble the filter as described in
section 7.6 – 7.9/ figures 5c & 5d
•
With the mixer tap filtered and hot/cold water taps open, slowly turn on the
mains water to allow the system to fill gradually
•
Check the system for leaks
9.6
If there are leaks from the mixer tap adaptor:
•
Turn off the mains water supply
•
Open the mixer tap filtered and hot/cold water taps to release pressure
from the system
•
Press in on the collar around the tubing where it enters the 7/16" tap
adaptor (N). See figure 8
•
Pull the tubing to release it from the adaptor and unscrew the adaptor from
the filtered water flexible supply pipe on the mixer tap
•
Check that the black sealing washer is correctly seated in the threaded
hole of the tap adaptor
•
Make sure the black sealing washer is undamaged and free from dirt and
particles
•
Screw the tap adaptor (N) to the filtered water flexible supply pipe on the
mixer tap - do not over tighten
•
Ensure sure that the tubing is cut square and it is not scratched or crimped
•
If the tubing is unevenly cut or scratched, cut off the damaged section
squarely and re install the tubing
O-ring
Figure 9
•
With the mixer tap filtered and hot/cold water taps open, slowly turn on the
mains water to allow the system to fill gradually
O-ring
•
Check the system for leaks
10. Prepare the filter for use
10.1 The 3 way mixer tap (Q) has an indicator light to inform the user when the
Body O-ring seal face inside
ceramic filter requires changing. The light flashes 'blue' when the filtered
water tap is operated, if the light flashes 'red' the ceramic filter requires
changing. Remove the plastic battery protection strip from the underside
of the mixer tap filtered water tap lever to enable the filter replacement
indicator function, see figure 2b
10.2 Open the mixer tap filtered water tap and run the water to waste for
10 minutes (or 15 litres)
10.3 Leave to stand for 24 hours to condition the ceramic filter element, then
run water to waste for a further 10 minutes. The filter is now ready for use
www.doulton.com