Baumer NE215 Instrukcja obsługi - Strona 36
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Licznik gotówki Baumer NE215. Baumer NE215 40 stron. Electronic preselection counter
Supplement to the operation manual with scaling factor
36
9.2 Modifications in Chapter 3: „Counter connection"
New pin assignment for pin 15: scaling on.
9.2.1Modifications in Chapter 3.3: „Assignment of signal inputs"
Pin 15 is for activating the setting of the scaling factor (line 22
programming level). Prior to sealing the pins the setting of the
scaling factor is activated by the signal trigger "scaling on" (pin 15).
Activation is realized by connecting pins 15 and 20, by a bridge from
18 to 19 or by 15 to 19, if 18 has to be connected to 20 (refer also to
page 8 "programming of input logic" in the operation manual).
After having set the scaling factor, the connection to pin 15 has to be
removed. Once being sealed, this pin is no longer accessible and the
scaling factor is indicated in the programming level without allowing
any alteration.
9.3 Modifications in Chapter 5: „programming the counter"
The scaling factor of the main counter is shown in programming line
22. Any modification is only possible if pin 15 is being activated (see
above).
Programming line 22: 2 2 1.0 0 0 0 Scaling factor main counter
Line 22
Scaling factor main counter
1.0000
Default
0.0001
Scaling range 0,0001
99.9999
up to 99,9999
Programming line 40 "function of the hour counter input" is
obsolete. The hour counter is always active after "on" .
NE215