Dover MOUVEX AS125 Instrukcja obsługi - Strona 16

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Pompa wodna Dover MOUVEX AS125. Dover MOUVEX AS125 18 stron.

Dover MOUVEX AS125 Instrukcja obsługi

6.1 Lubrication

The hose is lubricated with a special mixture. MOUVEX
lubricant is recommended to lengthen the service life of
the hose.
It is recommended to change the lubricant when :
• Replacing the hose.
• Replacing the hose due to maintenance operation.
• After 2000 hours of operation.
Amount of lubricant required :
AS125 pump require 120 liters of lubricant.
The minimum working or storage temperature for the
pump lubricant is 0°C (32°F).
For use / storage at lower ambient temperatures, it is
necessary to add ethylene glycol to the MOUVEX lubri-
cant. To maintain optimum lubrication, the volume of
ethylene glycol should remain between 4% and 6% of
the total volume of lubricant, and the total quantity of
lubricant present in the pump must be in compliance
with the value specified above.
In any case, the ambient temperature should never be
lower than -20°C (-4°F).

6.2 Hose

Some pumped liquids require the hose to be cleaned
after each operation to prevent solidification of the fluid
inside the hose.
The hose can be easily washed with a cleaning agent
that is compatible with the hose material and the pumped
product.
It is recommended that the hose be monitored so that it
can be replaced before any breakdown should occur.
Preventive replacement is advisable.
Temperature threshold values for the liquid pumped
depend directly on the materials that make up the hose.
Refer to technical characteristics on the cover page for
the corresponding values.
It is important to note that the temperature of the pumped
liquid influences the limits of use of the pump and that a
rise of the temperature of the pumped liquid has to come
along with a modification of the service pressure / of the
speed of rotation so as to respect the limits defined in §
TECHNICAL SPECIFICATIONS and eventually of a
modification of the shimming of the shoe as specified in
the § SHIMMING THE SHOES.
When required, you can contact our Technical Services
at any time to ask for the information you require.
NT 1101-P00 08.10 AS125 e

6. MAINTENANCE

6.3 Seals

16/18
6.3.1 SHAFT SEAL 26
The shaft seals 26 must be replaced if lubricant leakage
is observed near the drip strip, located on the rear side
of the pump body 1.
For this, disassemble the wheel (see § DISASSEM-
BLING THE WHEEL) and do the following operations
once this one put down :
1. Untighten the 8 screws 43.
2. Remove the tightness cover 25 and the seals 26.
3. Replace the seals 26 from the tightness cover 25.
They must be directed so that their springs must be
seen inside the pump body 1.
4. Insert the tightness cover 25 and its seals 26 in its
housing, taking care to not damage the seals.
5. Mount the tightness cover 25 with the 8 screws 43.
6.3.2 COVER SEAL 10
The cover seal 10 must be checked when removing the
cover 2 and replaced if necessary (see § DISASSEM-
BLING THE COVER).
6.3.3 WINDOW SEAL 46
The window seal 46 must be checked when removing the
window 15 and replaced if necessary (see § SETTING
OF PUMP AT SERVICE PRESSURE NEEDED).