REPAIR AND ASSEMBLY
SUBMERSION-MUFFLER KIT INSTALLATION
TOOLS NEEDED
1)
/
Inch socket
1
4
2)
/
Inch socket wrench
1
4
STEP 1
Place "Submersion/Muffler Plate Gasket" onto back
of intermediate and line up screw holes.
ALF-11010-E-01
WARNING
Prior to servicing the pump, ensure that the air
and fluid lines are closed and disconnected. While wearing personal
protective equipment, flush and drain process liquid from the
pump in a safe manner.
WARNING
Maintenance must not be performed when a hazardous
atmosphere is present.
STEP 2
Place "Submersion/
Muffler Plate" onto
"Submersion/Muffler
Plate Gasket" and line
up screw holes.
12
STEP 3
Insert screws into screw holes.
Tighten screws using a
socket and socket wrench
(recommended),
/
" wrench, or
1
4
flathead screw driver.
/
"
1
4
All-Flo