6. What should be done in the event of functional disorder?
6.1 Typical installation faults/consequences
Cause
Faulty pin allocation
Ambient temperature too high
Cylinder borehole too small
Cylinder borehole after welding too small
Pointed or sharp edges
Rude sensor handling
Welding after installation
Destruction of cables
Untight connectors
Distance washers missing or installed in wrong order
Faulty ground /shield connection
Consequences
No signal
Possible damage to components – no sensor signal
Component damage, because the sensor has been hammered
down too violently.
Component damage, because the sensor has been hammered
down too violently.
Damage to cables and conductors
Destruction of internal components, cables and connectors
High-energy voltage peaks or currents are fed to the sensor head,
damage of housing components or electronics components.
Short circuit, electronics failure
Liquid can penetrate into the sensor housing through cables or
strands and cause short circuit or corrosion of electronics com-
ponents.
Signal offset ≈ 5 mm
Output signal trouble or destruction of the electronics