Dover PSG MOUVEX SUBMERGED AM UNIT ON PLATE Instalacja, obsługa i konserwacja - Strona 12
Przeglądaj online lub pobierz pdf Instalacja, obsługa i konserwacja dla Pompa wodna Dover PSG MOUVEX SUBMERGED AM UNIT ON PLATE. Dover PSG MOUVEX SUBMERGED AM UNIT ON PLATE 13 stron. Submerged am unit on plate
9.1 Bearing lubrication
Lightly grease the ball bearing on the pump output shaft
during periodical lubrication of the vehicle.
Use high quality ball bearing grease, at high drop point.
NOTE - For submerged AM on plate units supplied with
reduction gear flanged to the pump, the reduction gear is
supplied greased for 10.000 running hours and requires
no maintenance.
10.1 Short duration (≤ 1 month)
WARNING
Toxic or hazardous
fluids can cause
serious injury.
MOUVEX pumps and motor-driven pumps are well lubri-
cated when delivered to protect the internal parts during
brief storage in a building where :
• the temperature remains between 10°C and 50°C.
• the relative humidity does not exceed 60%.
• exposure to vibration is limited.
• pump is stored in an area sheltered from bad wea-
ther and sun.
The pump must be scrapped in compliance with the regula-
tions in force.
NT 1010-I00 03 18 Submerged AM unit on plate e
9. MAINTENANCE
10. STORAGE
IF PUMPING HAZARDOUS OR TOXIC
FLUIDS, THE SYSTEM MUST BE FLUSHED
PRIOR TO PERFORMING ANY SERVICE
OPERATION.
11. SCRAPPING
9.2 3-way valve lubrication
Indicative list of greases for high temperatures
STATERMA 2
BP ENERGREASE HTG2
UNIREX N°3
UPTON 260
MOBIL TEMPS N°1
DARINA GREASE R2
CALORIS M 53
10.2 Long duration (> 1 month)
The recommendations from the manufacturer should be
followed if the pump is stored with its gear motor.
Pump ports should be filled with a non-corrosive liquid
that it compatible with the pump components in order to
prevent corrosion.
Unpainted external surfaces of the pump (e.g. shafts,
couplings, etc.) should be covered in some form of anti-
corrosion protection.
The bearing should be well greased. If the pump is to be
stored for more than the life of the grease, this one
should be replaced in time to prevent an excessive
degradation of its qualities.
Grease the valves : see § V
The best storage conditions are inside a building that
meets the conditions set out above.
If inside storage is not possible, the materials should be
covered to prevent direct exposure to sun and bad weather.
This protection should also prevent condensation.
The pump should be turned a few revolutions manually
every two months.
During this operation, particular care must be paid to the drai-
nage stages of the pump.
12/13
ELF
BP
ESSO
LABO INDUSTRIE
MOBIL OIL
SHELL
TOTAL
.
ALVES LUBRICATION