Dover HYDRO HYDSPD0093M Podręcznik użytkownika - Strona 10

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Kontroler Dover HYDRO HYDSPD0093M. Dover HYDRO HYDSPD0093M 20 stron. With evoclean

Dover HYDRO HYDSPD0093M Podręcznik użytkownika
3.OO programming (continued)
3.O2 Unit Parameters (continued)
2) Name – enter the name you wish to give the unit.
3) Enter machine type – Multitec 3.
4) Range
Washer extractors – the amount of washer extractors you are connecting the unit to.
Products in channel 1 – the number of chemical products you are connecting to the channel.
5) When all values have been entered click on Save at the bottom of the page.
3.O3 Channels Parameters
1) Click on Channels in the left-hand column, the below page will open.
2) Channel number – choose the channel you wish to program. For a Multi-Washer 3000 this will always be 1.
3) Name – name the channel.
4) Mode – choose from the following; time, flow sensor or flow meter. Flow sensor is the recommended mode for the Multi-
Washer 3000 with EvoClean.
5) Pump type – This must be set to EvoClean for the Multi-Washer 3000, and it should always be preselected as the default
pump type.
6) Water test – amount of water required to create the test within the channel in ml.
7) Flush
Flush type – For the Multi-Washer 3000 units, this setting will always be the water flush setting "Water Only".
8) Alarms
Skipped alarms – the amount of alarms that the unit will accept before the alarm buzzer Initiates on the unit and stops
dosages. Start at 1 and then change to 3 after initial commissioning.
9) Click on Save at the bottom of the page.
10
Unit Parameters