AmpleNess S52100G Podręcznik użytkownika - Strona 9
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Akcesoria do kamer AmpleNess S52100G. AmpleNess S52100G 20 stron. Storage lithium battery
No.
Name
Grounding
1
2
Power button
Capacity indicator
3
4
Alarm indicator
Running lights
5
6
DIP switch
External communication port
7
8
External communication port
External communication port
9
Reset button
10
Negative interface
11
Negative interface
12
13
Positive interface
14
Positive interface
Hanging ear
15
4.4 Battery Management System (BMS protection board) Function
4.4.1 Voltage Protection Function
Discharging low-voltage protection
In discharging, the over-discharge protection
will start and battery stops to supply
electricity if the voltage of any single cell is
lower
than
the
protection
protection will be dismissed after the voltage
of all cells returns to the range of rated
hysteresis value.
AMPLENESS Lithium Battery S52100G User Manual
Label
Ground wire
Power button. When switched to "ON", the
system
ON/OFF
external power supply; when switched to "OFF",
the system is turned off.
There are 4 green lights to show battery
SOC
capacity, and each green light represents 25%
of SOC.
Red light. The indicator light flashes when
ALM
alarming. When protected, the indicator light will
stay on.
Green light. In standby, the indicator light flashes.
RUN
When charging, the indicator light is always on.
The indicator flashes when discharging.
ADDR
Set address
CAN
Communication with external devices
RS485
Communication with external devices
RS485
Communication with external devices
Reset
Restart battery
Negative interface
" - "
Negative interface
" - "
Positive interface
" + "
Positive interface
" + "
Used to fix the battery box (two on the front
/
panel and three on both sides)
Charging over-voltage protection
In charging, the system will stop charging if
the voltage of battery module or any single
cell reaches to the protection value. The
value.
The
protection will be dismissed after the battery
module voltage and cell voltage return to the
range of rated hysteresis value.
7
Function Description
can be activated by the "SW" key or