Dovre 1800W Instrukcja instalacji i obsługi - Strona 2
Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Kominek wewnętrzny Dovre 1800W. Dovre 1800W 5 stron. Cast iron fireplace
Dovre 1800W, 2700W and
2000MFR Cast Iron Fireplace
Installation and Operating
Manual
These instructions should be read carefully
and saved by the
user for future reference
Never install appliance in tight fitting recess.
The installation should not be back filled with any
materials
Free air space should be allowed to the back, sides
and top of the appliance within the recess
We recommend that older chimneys without flue
liners are lined using a suitable liner of at least
200mm (150mm for Mini) diameter for use with
solid fuel burning appliances.
REGULATIONS
IMPORTANT
Before commencing the installation of your Dovre
appliance it is recommended that the instructions are
read and clearly understood.
HEALTH AND SAFETY AT WORK ACT 1974
The installer should comply with the Health and Safety
at Work Act 1974 and with particular reference to the
following:-
HANDLING
Adequate facilities should be provided for handling the
appliance.
GLASS
Extra care should be taken to avoid accidents and
breakage.
FIRE CEMENT
Care should be taken to avoid fire cement contacting the
skin. The material is caustic and in the event of contact
being made, wash off immediately with clean water.
CURRENT BUILDING REGULATIONS AND RELEVANT
CODES OF PRACTICE MUST BE OBSERVED.
ASSEMBLY
1
Remove all packaging materials
2
Remove all loose components including grates,
ashpan, fuel retainers, baffle plate and fixings pack.
Fit the door knobs, door latch and air slides (see
3
illustrations opposite)
4
For built in installations only. If a freestanding
application with a canopy is required proceed to 5.
For convenience, place 2 pieces of 50mm square
timber on the floor and lay the appliance on its back
on the two timbers battens. Fit the 4 cast iron legs
and levelling bolts.
NOTE: IF THE APPLIANCE IS GOING TO BE INSTALLED
WITH A CANOPY IN A FREESTANDING SITUATION IT
WILL NOT BE NECESSARY TO FIT THE LEGS.
Stand the appliance on a level surface in the upright
position and adjust the levelling bolts to ensure the
appliance is level side to side and front to back.
NOTE: THE DOORS ON YOUR DOVRE 2000 HAVE
BEEN ACCURATELY FITTED IN OUR FACTORY. (SEE
PAGE 3) IN CASE YOU DO FIND A PROBLEM IN
OPERATING THE DOORS, REPORT BACK TO YOUR
DEALER NOW. DO NOT ATTEMPT TO PROCEED WITH
THE INSTALLATION. DOVRE CAN NOT ACCEPT
RESPONSIBILITY FOR INCORRECT DOOR ALIGNMENT
AFTER THE APPLIANCE HAS BEEN INSTALLED.
5
Fit the top dome, flue damper if required (see
illustrations below) (2700W and 2000MFR models
only) and the flue spigots using a small amount of
fire cement on the joints.
Model: 2000MFR
Model: 2700W / 2000MFR
a&b
assembly of
Air Slides
c&d
assembly of
Door knobs/
Latches and
Legs
e
assembly of
Smoke Dome
f
assembly of
Flue Damper
2
APPLIANCE DOORS - IMPORTANT
NOTE: The doors on your
Dovre 2000 have been
accurately fitted in our factory.
In case you do find a problem
in operating the doors, report
back to your dealer now. Do
not attempt to proceed with
the installation. Dovre can not
accept responsibility for
incorrect door alignment after
the appliance has been
Fig.1
installed. Refer to page 2 of
this manual.
IMPORTANT: The following
stages should be used when
closing the doors on your
Dovre 2000 stove
1
Pull both sets of doors
together (see fig1).
2
Locate right hand side
door catch over adjustable
Fig.2
grub screw on left hand
door (see fig2).
3
Holding door knob push
left hand door.
4
While maintaining
pressure on left hand door
use right hand door knob
to pull door towards you
at the same time bringing
both doors together
(see fig3).
Fig.3
NOTE: Fixing brackets are supplied with the canopy but due to the variations in sizes of openings, it may
be necessary to support the canopy with your own adapted bracket arrangements.
INSTALLATION
FREE-STANDING INSTALLATIONS WITH CANOPIES
This type of application is often for large inglenook
fireplaces
with
wide
chimneys.
It
is
recommended that a liner be fitted if the chimney is
unlined.
There are two methods of installing the appliance on the
hearth.
1
Appliance mounted on a Dovre Base Support (part
ref MBP or SBP)
2
Appliance standing directly on the hearth
FOR FREE STANDING INSTALLATIONS IT WILL NOT BE
NECESSARY TO FIT THE SET OF FOUR LEGS SUPPLIED.
STEP 1
Position the appliance in the inglenook allowing a
minimum space of 100mm between the back of the
appliance and the back wall of the inglenook (see
illustration opposite).
STEP 2
Connect the appliance to the chimney using 316 grade
1mm thick stainless steel flue pipe. The pipe diameter
should be 200mm min (150mm for 1800W mini series). If
the flue damper has been fitted (2700W Standard and
2000MFR Super models only), it will be necessary to
install a cleaning access door in the flue pipe or chimney.
Your Dovre dealer will be pleased to advise on the best
method to use.
ON NO ACCOUNT SHOULD THE WEIGHT OF THE
FLUE LINERS BE CARRIED ON THE APPLIANCE. ALL
FLUES AND FLUE LINERS MUST BE SUPPORTED
INDEPENDENTLY OF THE APPLIANCE. FAILURE TO
FOLLOW THIS INSTRUCTION WILL LEAD TO
DISTORTION AND FRACTURING OF THE APPLIANCE
CASTINGS.
STEP 3
Fit the canopy ensuring that a minimum distance of
15mm is allowed between the canopy and the back wall
of the inglenook. This will allow the circulation of warm
air into the room.
WHEN FITTED WITH CANOPY CM3 - CS3
MINI
STANDARD
SUPER
A*
100
100
100
B*
15
15
15
C
75
75
75
D
410
625
695
E
950
1070
1070
F
1435
1770
1840
WHEN FITTED WITH CANOPY CM2 - CS2
A*
100
100
100
B*
15
15
15
C
75
75
75
D
410
625
695
E
700
685
685
F
1185
1385
1455
* Minimum Dimensions. All Dimensions in Millimetres.
3