8. CLEANING AND MAINTENANCE

Make sure that the appliance and gas valve are turned off before starting maintenance or cleaning.
Clean the appliance with a cloth that is soaked into warm soapy water and a disinfectant that will not harm
the food at the end of each working day.
Do not clean with direct or high pressure water.
Do not use materials that may scratch on the surfaces such as detergents with a corrosive content, wire
brushes etc. while cleaning the surface of the appliance.
In the event of a dangerous situation in the appliance, contact the authorized service. Do not allow
unqualified persons to interfere with the appliance.

9. TROUBLESHOOTING

TROUBLE
Gas is not supplied to the appliance.
Radiant is not on.
Radiant is on when the gas valve is
pressed, and then is off, when it is left.
Radiant is not on when the gas valve is
in the minimum position.
The appliance is operating, but the
flame is too large.
The skewers are not turning.
RISK ANALYSIS:
RISK
CAUSE
EXPLOSION
Gas Leakage
FIRE
Gas Leakage
Causes Explosion
HOT SURFACE
Wrong Gas
TEMPERATURE
Pressure
POISONING
High combustion
values
SUFFOCATION
Oil Ignition
SOLUTION
The gas valve in the installation is closed. Open the valve.
The gas valve of the appliance is closed. Open the valve.
There is air in the gas installation. Drain the air by holding the gas
valve.
The appliance has not been adapted to the appropriate gas type.
Check according to Table 2 and Table 3.
The injector is blocked. Call an authorized service.
The flame monitoring device (thermo element) is defective.
Call an authorized service.
Call an authorized service.
The appliance has not been adapted to the appropriate gas type.
Radiant is defective. Call an authorized service.
The power socket of the appliance is not plugged in. Plug it in.
The electric motor switch is turned off. Open.
PROTECTIVE
PRECAUTION
ACTION
*Leakage Control
Leakage
*Flame
Control
monitoring device
*N203-1 Gas
safety tests
*Periodic Control
*Leakage
*Flame
Control
monitoring device
*Caution plate
*Gas
*Use in Correct
Installation
Pressure
Control
*Information
*Supported
about correct
by service
combustion
access
*Periodic Control
*Cleaning
www.combisteel.com
PROTECTION
INFORMATION
*Periodic Control
*Cut Gas Flow
*Periodic
*Contact Service
Maintenance
*Periodic Control
*Cut Gas Flow
*Periodic
*Contact Service
Maintenance
*Cleaning
*Contact Service
*Read User
Manual
*Read User
*Contact Service
Manual
*Daily and
*Read User
Periodic Cleaning
Manual
7