Follett Symphony Plus 50 Series Instrukcja instalacji

Refrigeration pressure data

Water-Cooled ice machine refrigeration pressure
Discharge pressure/suction pressure
Condenser Water Temperature F/C
F/C
50/10
50/10
280/27
70/21
280/27
90/32
280/27

Compressor data

Compressor current draw
Air-cooled
Ambient air temp.
High side pressure (psi)
Low side pressure (psi)
Locked rotor amps
58.8
Gearmotor data
Gearmotor current
Locked rotor amps

Refrigeration system

Important: All service on refrigeration system must be performed in accordance with all federal, state and local
laws that pertain to the use of refrigerants. It is the responsibility of the technician to ensure that these requirements
are met.
Model
25/50CI425A, 25/50HI425A (air-cooled)
25/50CI425W (water-cooled)
4
25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A
70/21
90/32
285/29
290/31
psi
285/29
290/31
psi
285/29
290/31
psi
60 F/15.6 C
70 F/21.1 C
5.8A
6.1A
190
220
27
29
Split-Phase
1.8A-1.9A (nominal)
14A
80 F/26.7 C
90 F/32.2 C
6.2A
6.2A
250
290
31
33
PSC (permanent split capacitor)
0.8A-0.9A (nominal)
7A-14A (temperature dependent)
Charge
Refrigerant type
15 oz
R404A
9 oz
R404A
100 F/37.8 C
6.3A
330
36