§ Do not tilt unit further than 30° off vertical during uncrating or installation.
§ Dispenser bin area contains mechanical, moving parts. Keep hands and arms clear of this area at all times. If
access to this area is required, power to unit must be disconnected first.
§ Follett recommends a Follett water filter system be installed in the ice machine inlet water line (standard capacity
#00130229, high capacity #00978957, carbonless high capacity #01050442).
§ Prior to operation, clean the dispenser in accordance with instructions found in this manual.
§ Ice is slippery. Be sure counters and floors around dispenser are clean, dry and free of ice.
§ Do not block right side air intake or top air exhaust.

Specifications

16.00"
(40.7 cm)
Front View
Electrical
§ 115 V, 60 Hz, 1 phase, 11.0A
§ Connect to a 15A dedicated circuit.
Ambient
Air temp*
Water temp
Water pressure (psi/bar)
* Ambient air temperature is measured at the air-cooled condenser coil inlet.
Ambient water temperature is measured in the ice machine reservoir.
Plumbing
Dispenser drain
Water inlet
Note: Water shut-off recommended within 10 ft. (3 m) of dispenser. Drain to be hard-piped and insulated. Maintain at
least 1/4" per foot (20 mm per 1 m) run of slope.
2
12CI425A, 12HI425A
CAUTION!
22.625"
(57.5 cm)
4.00"
(10.2 cm)
23.5"
(59.7 cm)
Side View
100 F/38 C Max.
90 F/32 C Max.
70/5 Max.
32.00"
(82.6 cm)
18.00"
(45.8 cm)
50 F/10 C Min. Best performance below 80 F (27 C)
45 F/4 C Min. Best performance below 70 F (21 C)
10/0.7 Min.
12CI425A
3/4" MPT
3/8" FNPT
air exhaust
3/4" MPT drain
3/8" FPT
water inlet
air
intake
power cord (NEMA 5-15)
Rear View
12HI425A
3/4" MPT
3/8" FNPT