Follett VU155N Series Instrukcja instalacji, obsługi i serwisu - Strona 13
Przeglądaj online lub pobierz pdf Instrukcja instalacji, obsługi i serwisu dla Dozownik wody Follett VU155N Series. Follett VU155N Series 20 stron. Ice and water dispensers
Również dla Follett VU155N Series: Specyfikacje (2 strony), Instrukcja instalacji, obsługi i serwisu (20 strony)
Dispenser troubleshooting guide
Before calling for service
1. Check that ice is in the dispenser and that congealed cubes are not causing a jam.
2. Check that circuit breaker and switches are in ON position.
3. Check that drain pan, rear lid and top are on securely. If ajar, dispenser will not operate. When the top is off,
auger does not operate, even though the solenoids do (page 16).
4. Check that all drains are clear.
Note: For units equipped with Follett compressed nugget icemaker, see Icemaker Operation and Service
Manual for service and troubleshooting information.
Symptom
Ice does not dispense.
• Auger motor does not run
• Wheel motor does not run
Ice does not dispense.
• Auger motor runs
• Wheel motor runs
• Gate does not open
Ice does not dispense.
• Auger motor does not run
• Wheel motor runs
Ice does not dispense.
• Auger motor runs
• Wheel motor does not run
No ice in dispenser.
If problems persist after following this basic troubleshooting guide, call Follett's
technical service department at (800) 523-9361 or (888) 2-FOLLETT
or (610) 252-7301.
Possible cause
1. Power switch faulty or in OFF
position; loose connection.
2. Faulty dispense switch.
3. Faulty transformer.
4. Drain pan ajar.
5. Faulty drain pan safety switch.
1. Loose electrical connection.
2. Linkage problem between
solenoid and gate.
3. Faulty solenoid.
1. Loose electrical connection.
2. Faulty auger motor.
3. Faulty run capacitor.
1. Loose electrical connection.
2. Faulty wheel motor.
3. Faulty run capacitor.
1. Power switch in OFF position or
faulty.
2. Bin signal switches in OFF
position or faulty.
3. Faulty bin thermostat.
4. Faulty transformer.
5. Icemaker related problem.
6. Faulty run capacitor.
13
Solution
1. Turn power switch to ON position;
check connections.
2. Replace switch.
3. Replace transformer.
4. Check pan and reseat.
5. Replace switch.
1. Check connections.
2. Check linkage.
3. Replace solenoid.
1. Check connections.
2. Check auger motor.
3. Check run capacitor.
1. Check connections.
2. Check wheel motor.
3. Check capacitor.
1. Check switch and replace if
necessary.
2. Check switch and replace if
necessary.
3. Replace bin thermostat.
4. Replace transformer.
5. Refer to icemaker Operation and
Service Manual for diagnosing.
6. Check for power and bin signal on
icemaker PC board.