Amprobe AT-6000-R Skrócona instrukcja obsługi - Strona 5
Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Przyrządy pomiarowe Amprobe AT-6000-R. Amprobe AT-6000-R 10 stron. At-6000 series. advanced wire tracer
Non-Contact Voltage (NCV) and Passive Tracing
1
Set-up:
Receiver
NCV mode
1. Turn on the Receiver.
2. Continue pressing MODE button until the
Non-Contact Voltage (NCV) function is selected.
Note:
Transmitter
The Transmitter is not used in NCV mode.
Use this mode to scan for any energized wires
with passive tracing or to verify if a specific wire
is energized.
Amprobe
| [email protected] | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623)
®
Receiver:
Passive Tracing
1. Scan the target area with the Tip Sensor to find
the highest signal level.
2. While tracing, periodically adjust the sensitivity
to keep the signal strength near 50.
3. Increase or decrease sensitivity by pressing + or -
on the keypad.
Receiver:
Verify if a wire is Energized
1. Hold the Receiver with the Tip Sensor against
the wire.
2. For precise pinpointing of hot wire versus
neutral wire, increase or decrease sensitivity by
pressing + or - on the keypad.
©2018 Amprobe
®
For detailed specifications and ordering go to amprobe.com 6010521 A
3