Follett FZR4-ADA Instrukcja instalacji, obsługi i serwisu - Strona 3
Przeglądaj online lub pobierz pdf Instrukcja instalacji, obsługi i serwisu dla Zamrażarka Follett FZR4-ADA. Follett FZR4-ADA 20 stron. Undercounter freezer
Również dla Follett FZR4-ADA: Instrukcja instalacji, obsługi i serwisu (20 strony)
Welcome ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability, and outstanding
after-the-sale support. To ensure that this product delivers that same degree of service, we ask that you take a
moment to review this manual before beginning the installation. Should you have any questions or require technical
help at any point, please call our technical service group at (877) 612-5086 or +1 (610) 252-7301.
Before You Begin –––––––––––––––––––––––––––––––––––––––––––––––––––
After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If damage
is found, immediately notify the shipper and contact Follett Corporation so that we can help in the filing of a claim, if
necessary.
Check your paperwork to verify that you received the correct freezer. Follett configuration numbers are designed
to provide information about the type of freezer you are receiving. The following is an explanation of the different
model numbers.
Model Number
FZR5
FZR4-ADA
Specifications –––––––––––––––––––––––––––––––––––––––––––––––––––––
Series Specifications
§ FZR4-ADA: 31.25" (794mm) high, 3.3 cu ft (1.0 cu m) capacity, fits below 34" (864mm) high ADA-compatible
counter
§ FZR5: 34" (864mm) high, 4.0 cu ft (1.2 cu m) capacity, fits below standard 36" (915mm) high counter
Electrical Specifications
§ 115V, 60Hz, 1 phase
§ Full load: 8.0 A
§ Minimum circuit ampacity: 15 A
§ Maximum size of branch circuit overcurrent device: 15 A
Refrigeration Specifications
§ Refrigerant – R404A
§ Charge size – 10 oz
§ Maximum design pressures: High side – 383 psi; Low side – 175 psi
Installation Specifications
§ Ambient temperature must not exceed 86 F (30 C). Relative humidity 60%.
The front louvered panel must be kept free of any cabinet trim or obstructions to ensure proper ventilation of
the refrigeration system.
CAUTION!
Equipment must be wired according to local NEC codes.
Unplug equipment before servicing.
Be sure to find adequate storage for products prior to unplugging equipment.
Item Number
Stackable/Use with
FZR5-000000
FZR5-00ST00
FZR4-000000
FZR4-00ST00
Pedestal*
No
Yes
No
Yes
FZR Undercounter Freezer
3