Follett VU155B Instrukcja instalacji, obsługi i serwisu - Strona 7

Przeglądaj online lub pobierz pdf Instrukcja instalacji, obsługi i serwisu dla Dozownik napojów Follett VU155B. Follett VU155B 20 stron. Ice and beverage dispensers

Follett VU155B Instrukcja instalacji, obsługi i serwisu

Field wiring diagrams

Note:
Field wiring diagrams are intended to aid electricians or technicians in understanding how equipment
works. All field wiring must be installed in accordance with all local and NEC codes.
Electric
Power
Source
Installing optional auto-fill ice machine kit(s)
Correct installation of RIDE
installation manual packed with ice machine for important details on ice transport tube run, ventilation
requirements and other installation requirements. Failure to comply with instructions may void warranty.
To start and operate dispenser
1. Follow detailed cleaning instructions in service manual before operating dispenser.
2. On units with Follett integral ice water bath beverage cooling ("B" models) only, slowly pour water into ice
water bath area to fill empty bath and submerge coils. Coils are submerged when water starts to flow out
overflow drain. DO NOT SPLASH WATER ON ELECTRICAL BOX. Once filled with water, add ice to bath
until ice covers top of water bath.
3. For manual load units, remove front drain pan or rear lid and fill storage area with approved ice.
Note: Follett manual load dispensers can accommodate most cube/cubelet ices up to 1" square, or Follett
compressed nugget ice. Crushed, flake, bagged, nugget or congealed ice cannot be used. Use of these
ices can jam dispenser and void warranty. Separate any "waffle-like" sections of cubes before adding to
dispenser. For ice compatibility questions, please call Follett customer service at (877) 612-5806
or +1 (610) 252-7301.
4. Turn power switch located on dispenser control box to ON position.
5. For automatic fill units, follow detailed instructions in ice machine installation section of installation manual,
then turn ice machine (bin signal) switch(es) located on dispenser control box to ON position and begin to
make ice.
6. When dispenser has at least 6" (153 mm) of ice in storage area, test operation.
DISPENSER
LEFT JUNCTION BOX
RIGHT JUNCTION BOX
W
BL
B
Y
RD
GND
GRN
model ice machines is critical to proper performance of ice machine. Refer to
CONVERTER BOX
TO ICE MACHINE 1
7
CONVERTER BOX
TO ICE MACHINE 2