DPM FL27 Podręcznik - Strona 5
Przeglądaj online lub pobierz pdf Podręcznik dla Sprzęt oświetleniowy DPM FL27. DPM FL27 17 stron. Led floodlight
SAFETY INSTRUCTIONS
1. User's manual is a part of the product and it should be
stored with the device.
2. Before use read the user's manual and check the techni-
cal specification of the device and strictly obey it.
3. Operating the unit contrary to the instruction manual and
its purpose may cause damage to the unit, fire, electric
shock or other hazards to the user.
4. The manufacturer is not liable for any damages to persons
or property caused by improper use, contrary to its intended
purpose, the technical specifications or the user's manual.
5. Before use check if the device or any of its components is
not damaged. Do not use damaged product.
6. Do not open, disassemble or modify the device. All repairs
may only be made by an authorized service center.
7. Use the device only in dry interior rooms. International
Protection Rating for the device is IP20.
8. The device should be protected against: dropping and
shaking high and low temperatures humidity, flooding
and splashing dire ct sunlight chemicals and other
factors that could affect the device and its operation.
9. The device should be cleaned with a dry and soft cloth.
Do not use abrasive powders, alcohol, solvents, or other
strong detergents.
10. Product is not a toy. The device and packaging must be
kept out of the reach of children and animals.
FEATURES
LED floodlight is used to illuminate buildings, gates, gardens,
car parks, cellars etc. It is suitable for indoor and outdoor use
(IP65). Black aluminum housing.
TECHNICAL SPECIFICATION
Input voltage:
colour temperature:
power factor:
colour rendering index:
beam:
lifetime:
ON/OFF switch cycles:
operating temperature:
degree of protection
warm-up time:
FL27-10W
10 W
700 lm
FL27-20W
20 W
1400 lm
FL27-30W
30 W
2100 lm
FL27-50W
50 W
3500 lm
Warning! Floodlight is not suitable for accent lighting. Do not
use in dimmed circuits. Floodlight can be dimmed only by LED
dimmers. LED modules not replaceable.
INSTALLATION
Warning! Electrical connections should be made by qualified
electricians in accordance with relevant national standards
and regulations While drilling the mounting holes, pay atten-
tion to the location of electrical cables and other installations.
It is recommended to use a detector for detecting AC wires and
pipes in walls, such as DPM KC098YB or V31 The floodlight
AC 230 V ~ 50 Hz
4000 K (neutralny biały)
PF > 0,5
R a > 70
120º
max. 25000 h
max. 12500
od –15ºC do +40ºC
IP65
instant full light
95 mA
110 x 90 x 25 mm
190 mA 140 x 120 x 25 mm
160 mA 170 x 150 x 28 mm
270 mA 210 x 180 x 30 mm
5