Bosch Ascenta SHE5AM02UC Instrukcje naprawy - Strona 13

Przeglądaj online lub pobierz pdf Instrukcje naprawy dla Zmywarka Bosch Ascenta SHE5AM02UC. Bosch Ascenta SHE5AM02UC 50 stron. Quick reference instructions
Również dla Bosch Ascenta SHE5AM02UC: Instrukcja instalacji (21 strony), Podręcznik dotyczący energii (2 strony), Rozpocznij (2 strony), Instrukcja naprawy (27 strony)

Bosch Ascenta SHE5AM02UC Instrukcje naprawy
4.5

Drain pump

The BLDC 9-vane drain pump has variable speed and direction.
The power control module controls speed and direction, detects
end of draining and blocked rotor and corrects locked rotor
conditions.
The dishwasher won't run if the drain pump is
disconnected or disabled.
To remove the drain pump, rotate it clockwise and pull it out.
4.5.1
Solving installation issues
Often improper installations, not drain pump issues, cause
dishwashers to not drain properly.
 Must have drain hoses with high loops (min. 20" high)
or drains with air gaps.
 Drain hoses are 6' long and can be up to 10' long.
 Secure drain hoses to rear of dishwashers with non-
metal bands.
 Make sure drain hoses aren't kinked.
702_58300000130262_ara_en_c
4.5.2
Cavitating
Cavitating may occur in any type of pump when impellers spin
faster (from low inlet or outlet pressure), creating air pockets
around impellers.
Cavitating pumps can be noisy.
gaps/high loops keep water contacting pump outlets, preventing
air pockets from forming.
4.5.3
Siphoning
Siphoning may occur in any type of drain pump when low water
flow allows a siphon (suction) to develop, pulling waste water
back into the pump.
Sump check valves along with air
gaps/high loops prevent siphons from being created.
Air