Bosch Integra SHX43C06UC Instrukcja instalacji - Strona 7
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Zmywarka Bosch Integra SHX43C06UC. Bosch Integra SHX43C06UC 50 stron. Bosch integra shx43c02uc: installation instruction
30"
(762mm)
21"
(533mm)
Figure 4
Dishwasher Electrical Rating
V
l o
s t
H
e
r
z t
A
m
p
1
2
0
6
0
3" - 4"
( 75mm - 100mm)
3/8" - 1/2"
( 8mm - 13mm)
Figure 5
Electrical Preparation
e
e r
s
W
t a
s t
1
4 ,
5
0
1
5
(
m
a
) x
ELECTRICAL PREPARATION
WARNING
Electrical Shock Hazard
To avoid electrical shock, do not work on an
energized circuit. Doing so could result in serious
injury or death. Only qualified electricians should
perform electrical work. Do not attempt any work
on the dishwasher electric supply circuit until you
are certain the circuit is
de-energized.
WARNING
Fire Hazard
To avoid a fire hazard, make sure electrical work
is properly installed. Only qualified electricians
should perform electrical work.
Electrical Supply
The customer has the responsibility of ensuring that the
dishwasher electrical installation is in compliance with all
national and local electrical codes and ordinances. The
dishwasher is designed for an electrical supply of 120V,
60 Hz, AC, connected to a dishwasher-dedicated,
properly grounded electrical circuit with a fuse or breaker
rated for 15 amps. Electrical supply conductors shall be a
minimum #14 AWG copper wire rated at 75°C or higher.
Regardless of where the electrical supply cable enters the
enclosure (following the guidelines on page 8), position
the cable 21" (533mm) from the enclosure's left side, as
shown in Figure 4. Extend the cable 30" (762mm) from
the enclosure's back, as shown in Figure 4.
Remove 3" - 4" (75mm - 100mm) of the cable's outer
casing, as shown in Figure 5, then remove 3/8" - 1/2"
(9 - 13mm) of insulation from each wire, as shown in
Figure 5.
5