AirStage AS 7UF Instrukcja obsługi - Strona 2

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Klimatyzator AirStage AS 7UF. AirStage AS 7UF 2 stron. Compact wall mounted type air conditioner

PREPARATION
LOAD BATTERIES (R03/LR03 x 2)
1. Press and slide
the lid.
2
2. Insert batteries.
Be sure to follow the
polarity markings indi-
1
cated in the compart-
3
ment.
3. Slide back the lid.
SET THE CURRENT TIME
1. Press the TIME
ADJUST button.
2. Press the
/
2
button.
3. Press the TIME
1, 3
ADJUST button.
REMOTE CONTROLLER HOLDER
To set the remote con-
1
troller in the holder
1. Insert.
2
2. Press in.
To take out the remote
1
controller from the
holder
2
1. Slide up.
2. Pull out.
MANUAL AUTO OPERATION
Use the MANUAL AUTO operation when the remote
controller is lost or unavailable.
MANUAL
AUTO
Press
Press the MANUAL AUTO button on the main
unit control panel.
To stop operation, press the MANUAL AUTO button again.
NOTES
• Each press of the MANUAL AUTO button alternates
operation and stop.
• When the air conditioner is operated from the main
unit, "HEAT & COOL MODEL" will operate COOL or
HEAT. "COOLING ONLY MODEL" will operate AUTO.
• The fan speed is selected to "AUTO" and the tempera-
ture setting will be set to 23 °C.
SLEEP TIMER
To set or change the SLEEP Timer
1. Press the
(SLEEP) button.
2. Press the
/
button.
Adjust the OFF TIME.
To cancel the SLEEP Timer
Press the
button.
Select
(TIMER RESET).
The air conditioner will return to normal operation.
MASTER CONTROL
Press the
button while in operation.
NOTES
AUTO
COOL
DRY
FAN
HEAT
"HEAT & COOL MODEL" cannot operate AUTO and FAN.
"COOLING ONLY MODEL" cannot operate HEAT.
TEMPERATURE
Press the
/
button while in operation.
Temperature setting range
NOTES
AUTO • • • • • • • 18 to 30 °C
HEAT • • • • • • • 16 to 30 °C
COOL/DRY • • • 18 to 30 °C
The thermostat setting should be considered a stan-
dard value, and may differ somewhat from the ac-
tual room temperature.
AIR DIRECTION (UPPER AND LOWER)
Press the
button while in operation.
For swing operation:
Press the
button while in operation.
Stop the setting by pressing it again.
NOTES
(1) Airflow direction
Cooling mode • • • • 1 to 3
Heating mode • • • • 1 to 6
(2) Range of swing
The range of swing is relative to the currently set airflow
direction.
1, 2, 3 • • • • • 1 to 3
4, 5, 6 • • • • • 4 to 6
1
2
3
4
5
6
NOTES
(1) The remote controller must be pointed at signal receiver to operate correctly.
(2) Operating range : About 7 meters.
(3) Beeping sound
• When a signal is properly received by the air conditioner, a beeping sound will be
heard twice.
• If an invalid signal is received by the air conditioner, a beeping sound will be heard 5
times.
• If no beeping sound is heard, press the remote controller button again.
(4) The buttons except the SLEEP, TIME ADJUST and ACL buttons can only be selected
while in operation mode.
OPERATION
ON / OFF TIMER
1. Press the
button.
Select
(OFF TIMER) or
NOTES
RESET
PROGRAM TIMER (OFF
2. Press the
/
Adjust the OFF or ON TIME.
PROGRAM TIMER
To set or change the PROGRAM Timer
1. Press the
button.
Select
(OFF TIMER).
2. Press the
/
Adjust the OFF time.
3. Repeat Step 1 and 2 to adjust ON time.
4. Press the
button.
Select
(PROGRAM TIMER).
(If the ON timer has been selected to operate
first, the unit will stop operating at this point.)
To cancel the PROGRAM Timer
Press the
button.
Select
(TIMER RESET).
The air conditioner will return to normal operation.
FAN SPEED
Press the
button while in operation.
NOTES
(Select the fan speed
automatically.)
START / STOP
Each press of the
operation and stop.
(5) PROGRAM timer
• The PROGRAM timer allows you to integrate OFF timer and ON timer operations
in a single sequence.
• The first timer function to operate will be the one set nearest to the current time.
(6) SLEEP timer
To prevent excessive warming or cooling during sleep, the SLEEP timer function au-
tomatically modifies the set temperature in accordance with the time setting. When
the set time has elapsed, the air conditioner completely stops.
(7) When connecting with other remote controllers, the indoor unit might be controlled by
the other remote controllers.

CLEANING AND CARE

CLEANING THE INTAKE GRILLE AND THE
AIR FILTER
(ON TIMER).
1. Remove the intake grille and the air filter.
1 Place your fingers at both
lower ends of the grille
OFF TIMER
ON TIMER
panel, and lift forward.
ON, OFF
ON)
2 Pull down the knob.
button.
3 Open the intake grille , and
lift the intake grille upward,
until the axle at the top of
the intake grille is removed.
4 Lift up the air
filter 's handle,
disconnect the
two lower tabs,
and pull out the
air filter.
button.
2. Cleaning
Intake grille : Remove dust with a vacuum cleaner, wash
the grille with warm water, and then dry with a clean and
soft cloth.
Air filter : Remove dust with a vacuum cleaner or by wash-
ing. After washing, be sure to allow it to dry thoroughly in
a shady place before reinstalling.
3. Replace the intake grille and the air filter.
1 Align the sides of
the air filter with
the panel, and
push in fully, mak-
ing sure the two
lower tabs are returned
properly to their holes in
the panel.
2 The fixing axle of the in-
AUTO
HIGH
MED
LOW
take grille is installed on
the front panel.
3 Lay down the intake grille.
CAUTION
button alternates
Don't turn on the indoor unit when the intake grille has been
removed.
NOTES
• When used for extended periods, the unit may accumulate dirt
inside, reducing its performance. We recommend that the unit
be inspected regularly, in addition to your own cleaning and
care.
For more information, consult authorized service personnel.
• Dust can be cleaned from the air filter either with a vacuum
cleaner, or by washing the filter in a solution of mild detergent
and warm water.
• When cleaning the unit, do not use water hotter than 40 °C,
harsh abrasive cleansers, or volatile agents like benzene or
thinner.
• Do not expose the unit to liquid insecticides or hairsprays.
• During periods of normal use, the air filters should be cleaned
every two weeks.
• When shutting down the unit for one month or more, first allow
the fan mode to operate continuously for about one-half day to
allow internal parts to dry thoroughly.
3
3
1
Intake grille
1
Fixing
axle
Knob
2
2
Air filter handle
4
Hooks (two places)
1
1
Hooks (two places)
Fixing axle
2
Mounting
shaft
Knob
3
Intake
grille
Fixing
axle
Knob