Draper Access XL Instrukcja instalacji i obsługi
Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Ekran projekcyjny Draper Access XL. Draper Access XL 5 stron. Draper access xl electric projection screen
Również dla Draper Access XL: Instrukcja obsługi (8 strony), Instrukcja instalacji i obsługi (5 strony)
Access XL 220V Electric Projection Screen by Draper
These Installation/Operating Instructions are available in the official language of
the country where you purchase the product. Please contact your distributor to
request a copy.
Vous pourriez demander les instructions d'installation et d'opération traduises
dans la langue officielle du pays ou vous achetez le produit. Veuillez demander à
votre distributeur.
Die Gebrauchsanweisung für Installation und Konstruktion sind in der offiziellen
Sprache des Landes, indem Sie das Produkt gekauft haben, vorhanden. Fragen
Sie die jeweilige Verkaufs-Abteilung.
1 Read instructions through completely before proceeding.
2 Follow instructions carefully. Installation contrary to instructions
invalidates warranty.
3 Pick up screen case from ends only. Picking case up at other points will
damage case and may damage fabric.
4 To insure a safe installation, the entire weight of the unit MUST BE
supported by outermost ceiling mounting brackets (those on ends). Don't
use intermediate brackets to lift or support the weight of the screen.
5 To eliminate the possibility of the case warping, outermost ceiling
mounting brackets (those on ends) must be located centered above
the interior roller mounting brackets (+/-102mm).
6 Entire bottom of screen case should be unobstructed to permit access to
bottom panel for making electrical connections or servicing.
7 Screen should be installed level (using a carpenter's level).
8 Operating switch(es) packed separately in screen carton. Do not discard
with packing material.
9 An appropriate disconnect device shall be provided as part of the building
installation.
10 Screen operates on 220V, 50 Hz., 1ph. with max 2.1 amp draw.
NOTE: Screen has been thoroughly inspected and tested at factory and found
to be operating properly prior to shipment.
These instructions are meant as a guide only. They do not imply any responsibility
on the part of the manufacturer for improper installation or faulty workmanship at
the jobsite.
Hanging Screen
When locating viewing surface and checking clearance for screen operation,
remember surface is centered in the length of the case. Regardless of mounting
method used, the following points apply:
1 Engage each ceiling mounting bracket with top of housing as shown below and
tighten nuts. The outer two brackets should be centered above the location of
the interior roller brackets (+/-102mm). The remaining two brackets should be
equally spaced between the outermost brackets.
2 Screen should be lifted into position only by the outermost ceiling mounting
brackets (those on ends). Keep case level by lifting each end simul-
taneously to prevent surface damage. Never attempt to lift screen along
its length.
3 The entire weight of the unit MUST BE supported by the outermost mounting
brackets to provide a secure installation (those on ends). Do not use
intermediate brackets to lift or support the weight of the screen.
4 Screen should be positively and securely supported so that vibration or even
abusive pulling on viewing surface will not weaken installation.
Typical Installation
/
" electrical cutout
7
8
Suitable for use in environmental air space in accordance with Section
300-22(c) of the National Electrical Code, and Sections 2-128, 12-010(3) and
12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.
Copyright © 2014 Draper Inc.
Form AccessXL220_Inst15
Installation/Operating Instructions
Caution
Slots along top of case
permit brackets to be
set at an angle
Case dimensions
on page 3.
Alternate
Installation
(additional set of
brackets required
but not included).
Two intermediate
brackets must be
spaced evenly
from ends.
Printed in U.S.A
US Patent Nos. 6,137,629; 6,421,175; 6,532,109; 6,816,308; 7,559,707
5 Installer must insure that fasteners used are of adequate strength and
suitable for the mounting surface chosen. Installer must also insure that
ceiling structure is of adequate strength. Supporting hardware (chains,
cables, 9.5mm rods, etc.) must be essentially vertical.
6 Entire bottom of case must be readily accessible after installation is complete.
7 Front, back and top of case must be straight—not forced to warp or bow
(see note 5 in caution box).
8 Do not use case to support adjacent sections of ceiling.
9 If case is painted on location, removal of roller/fabric assembly is recommended
prior to painting. If not removed, slot on bottom of case should be shielded to
protect viewing surface from paint splatters or overspray.
10 Do not seal unit in ceiling until electrical connections have been made and
screen has been operated successfully.
Electrical Connections
Screen operates on 220V, 50 Hz., 1ph with max 2.1 amp current draw.
Junction box is located just above the bottom access panel at left end of screen
(standard, right end may be specified). Remove the bottom access panel for
access to the junction box cover. (See Bottom Access Panel Removal instructions
below.) Remove four (4) hex head screws that secure the cover to the junction box
to expose the black, brown and blue pigtail leads and the green/yellow ground wire
per wiring diagram on page 4.
If optional low voltage control or video interface control is specified and factory
installed, please refer to wiring diagrams on page 5.
Screen is shipped with internal wiring complete and control switch (es) fully boxed.
Wire to connect screen to switch (es) and switch (es) to power supply should be
furnished by installer. Connections must be made in accordance with attached
wiring diagram, and wiring must comply with national and local electrical
codes.
All operating switches should be "off" before power is connected.
Motor Type
506S2PA, 510S2PA, 515S2PA,
506S2 ILT2, 515S2 ILT2
525A2PA, 535A2PA, 535A2 ILT2
NOTE: Excessive continuous operation may cause the motor to over
heat. If this happens the motor will shut off until it cools to a normal
operating temperature.
Shipping Brackets
If provided, remove shipping brackets by following Figure 2.
Bottom Access Panel Installation/Removal
Removal and replacement of the bottom closure panel requires two people
positioned about 152cm from each end of the panel.
1 Before removing bottom closure, you must first remove screws at each
end of case and slide the closure clips inward, away from the outside of
the case (see Fig. 3).
Case
Front of case
removed for
clarity
Closure
If you encounter any difficulties installing or servicing your Access XL screen, call your
dealer or Draper, Inc., in Spiceland, Indiana, 765/987-7999 or fax 765/987-7142.
Duty Cycle
1 minute on, 3 minutes off
1 minute on, 10 minutes off
Dowel