Draper D13/5A Instrukcja obsługi - Strona 5
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Wiertarka Draper D13/5A. Draper D13/5A 20 stron. 5 speed bench drill press
CONNECTING YOUR MACHINE TO THE POWER SUPPLY:
To eliminate the possibility of an electric shock your machine has been fitted with a BS approved, non
rewireable moulded plug and cable which incorporates a fuse, the value of which is indicated on the pin
face of the plug. Should the fuse need to be replaced an
same rating, marked thus
a replacement fuse cover is required, ensure it is of the same colour as that visible on the pin face of the
plug (i.e. red). Fuse covers are available from your Draper Tools stockist.
If the fitted plug is not suitable, it should be cut off and destroyed. *The end of the cable should now be
suitably prepared and the correct type of plug fitted. See below.
*WARNING:
A plug with bare flexible wires exposed is hazardous if engaged in a live power socket outlet.
WARNING: THIS APPLIANCE MUST BE EARTHED.
Green and Yellow - Earth, Blue - Neutral, Brown - Live.
As these colours may not correspond with the coloured markings identifying the terminals in your plug,
proceed as follows.:
The wire which is coloured green and yellow must be connected to the terminal in the plug which is
marked with the letter 'E' or by the earth symbol
The wire which is coloured blue must be connected to the terminal which is marked with the letter 'N' or
coloured black or blue.
The wire which is coloured brown must be connected to the terminal which is marked with the letter 'L' or
coloured red or brown.
N.B. Three phase machines must be connected by a qualified electrician.
EXTENSION LEAD CHART:
Extension lead sizes shown assure a voltage drop of not more than 5% at rated load of tool.
Ampere rating
(on Name plate)
Extension cable length
7.5m
15m
22.5m
30m
45m
POWER SUPPLY
. The fuse cover is detachable, never use the plug with the cover omitted. If
3
0.75
0.75
0.75
0.75
0.75
approved BS1362 fuse must be used of the
or coloured green or green and yellow.
6
Wire Size mm
0.75
0.75
0.75
0.75
1.25
- 5 -
10
13
2
1.0
1.25
1.0
1.5
1.0
1.5
1.25
1.5
1.5
2.5