Draper SKYLIGHT 2 FLEXSHADE Instrukcja obsługi - Strona 6

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Wyposażenie wnętrz Draper SKYLIGHT 2 FLEXSHADE. Draper SKYLIGHT 2 FLEXSHADE 8 stron. Motor operated skylight shades for very large applications

Draper SKYLIGHT 2 FLEXSHADE Instrukcja obsługi
SKYLIGHT 2 FLEXSHADE

Section 5 - Limit Setting

Please Note: These instructions are for standard motors. For instructions on setting limits on RTS motors, contact Draper, Inc.
Caution: If limit is not set, hem bar could come into contact with the mounting brackets, creating a pinch point and possibly damaging the unit.
1. Determine which direction of fabric travel corresponds with arrows on motor.
2. Operate shade to desired "Closed" stop position. Adjust the limit by turning the proper socket toward the "+" or "-".
3. Operate shade to desired "Open" stopping position. Adjust the limit by turning the proper socket toward the "+" or "-".

Section 6 - Dimensions

Shade Length - 11 "(REF)
9"
(229mm)
Fully Open
Shade Length - 14 "(REF)
5
"
(148mm)
®
Shade Length
(302mm)
(378mm)
Stay and Seam
D=
Placement
(if required)
This Side
Faces the Window
This Side
Faces the Room
2 "
(73mm)
Fully Closed
3"
(76mm)
Hem Bar
Width
5 "
(133mm)
to fabric panel
finished edge (REF)
3"
(76mm)
3
"
5 "
(94mm)
(146mm)
Max.
page 6 of 8