① Read in struc tions through com plete ly before pro ceed ing.
② Follow instructions carefully. Installation con trary to in struc tions
invalidates warranty.
③ Entire bottom of headbox should be unobstructed to permit access to
bottom panel for electrical connections or servicing.
④ Headbox should be installed level (using a carpenter's level).
⑤ Nothing should be fastened to shade dowel or shade fabric.
⑥ Shade operates on 110-120V, 60 Hz. current.
NOTE: Unit has been thoroughly inspected and tested at fac to ry and found
to be operating properly prior to shipment.
Headbox Installation
Suspended Installation—
① Position backets at a 45º angle on the top of the rear housing, then rotate
into place in the grooves provided (see Fig. 1).
② Locate bracket as required for threaded rod, chain or cable, and tighten
set screws to hold bracket in place.
Slots along top of case permit
brackets to be set at an angle
Typical Installation
See page 2 two
dimensions.
Ceiling (Surface) Installation—
① Open bottom access panel. A spring latch at each end of the trap door
holds this assembly closed. In some shades there may also be a spring
latch near the center of the case. To gain access to inside of case, disen-
gage spring latch at each end of the case (and near the center of the case,
if applicable) by sliding the latch lever towards the center of case, then
pull down slightly on the trap door assembly. The latch levers are some-
what concealed from view. Locate these with the trap door open by feeling
for the vertical latch lever above the door about 3" from case endcaps and
near the center of the case. The assembly will swing down, opening about
135°. Pivot the prop arms at each end of the trap door assembly towards
the ends of case. Prop arms engage with a hole in each endcap to hold
the trap door assembly fully open. To close the trap door assembly disen-
gage prop arms from endcaps and pivot these over the access panel.
Swing the trap door as sem bly upward, stopping just before the latch
levers hit the bottom fl anges of the endcaps (and center of case where
appropriate). Pull levers of latches towards center of screen case to allow
the trap door assembly to be pivoted to its closed position. Make sure that
the spring latch levers engage fully with case endcaps (and center of case
where appropriate).
Copyright © 2010 Draper Inc. Form UltimateAccessFlexShade_Inst10-R Printed in U.S.A.
Installation/Operating Instructions
Ultimate Access FlexShade by Draper
Caution
Alternate Installation
(additional set of
brackets required
but not included)
Figure 1
®
Caution: Beware of pinch
points along closure
② Drill holes through the top of the rear hous ing as required (see Fig. 2).
③ Position housing against ceiling and transfer mounting hole locations.
④ Install appropriate anchors.
⑤ Mount housing to ceiling.
Note: Roller mounting brackets are factory installed in the housing.
① Compress and insert spring loaded pin end into its bracket.
② Insert operator end into bracket (see Fig. 3).
③ Plug shade into junction box.
Electrical Con nec tions
Screen operates on 110-120V, 60 Hz. cur rent.
Junc tion box is lo cat ed in the upper left corner of the headbox.
Open the access panel/trap door for access to the junction box cover. (See
bottom access panel/trap door opening and closing instructions under "Ceiling
(Surface) Installation".)
Remove two (2) hex head screws that secure the cover to the junction box to
expose the red, black, and white pigtail leads and the green ground wire per
wiring diagram on back page.
Shade is shipped with internal wiring complete and control switch(es) fully
boxed. Wire to connect shade to switch(es) and switch(es) to power supply
should be furnished by installer. Con nec tions should be made in ac cor dance
with attached wiring diagram, and wiring should comply with national and
local electrical codes.
All operating switches should be "off" before power is connected.
Please Note: For low voltage wiring requirements, Draper recommends con-
sulting with a professional low voltage electrical contractor. It is very important
that shielded and stranded CAT 5 cable be used to prevent any electrical
interference.
Each Draper Solar Control Shade is tested to ensure proper operation.
Even with this testing, some fi eld adjustments may be needed for telescoping.
If the shade is telescoping, place a piece of high quality gaffer tape about 1"
wide on the exposed roller (where the fabric will cover it) on the side that you
want the fabric drawn toward. For example: if the fabric is tracking to the left,
place the tape on the right side.
If you encounter any diffi culties installing or ser vic ing your Ultimate Access FlexShade,
call your dealer or Draper, Inc., in Spiceland, Indiana, 765/987-7999 or fax 765/987-7142.
Shade Assembly
Figure 3
Field Adjustments