Bake Element
The 240V 2400W bake element is concealed in the base of the oven.
Access to the rear of the unit is necessary when replacing the
element.
Refer to the Element Strip Diagram section to test the bake element at
the control module. A Bake Element Relay Test is also available in
Service mode. See the Service Mode section for additional
information.
If the wires are disconnected from the element terminals, an
ohmmeter can be used to check for resistance of ~24 ohms.
6.9.1
Replacing the Bake Element
1. Remove the screws securing the right and left side trim pieces to
the cabinetry.
2. Carefully slide the oven out of the cutout to gain access to the
bake element from the rear of the unit.
3. Disconnect the wires from the element terminals.
4. Remove the screws securing the bake element access panel.
5. Bend the access panel downward to expose the element.
6. Holding the terminal plate, pull the bake element outward, leaving
the insulation in place; a putty knife or similar tool may be useful.
Figure 46 Removing the bake element
Copyright by BSH Home Appliances Corporation
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
JUNE 2014
6.10 Temperature Sensor
The PT1000 temperature sensor is in the upper left corner of the
cavity, with two screws securing it. An ohmmeter can be used to
check the resistance of the sensor. Normal ranges (based on cavity
temperature) are shown in Table 6.
Table 6 Normal resistance readings for temperature sensor
6.11 Control Module (Relay Board) and Daughter
NOTICE
More than 75% of the control modules returned to the factory are fully
functional. Before diagnosing a bad control module, be sure to
disconnect and reconnect each wire/wire harness.