Because 8 10/100/1000M Base-T ports of S2510-B support the MDI/MDIX auto-identification of the cable, S2510-B
can adopt five classes of direct-through/cross network cables when it connects other Ethernet terminals.
Figure 3- 5 Connecting the gigabit Base-T port and any other Ethernet terminal
No.
1
Sending the normal phase of the data
2
Sending the paraphase of the data
3
Receiving the normal phase of the data
4
Sending the normal phase of the data
5
Sending the paraphase of the data
6
Receiving the paraphase of the data
7
Receiving the normal phase of the data
8
Receiving the paraphase of the data
The direct-through or cross network cable has the function of auto-identification, so the
five classes of direct-through/cross network cables can be used to connect other
Ethernet devices.

3.4 Checkup After Installation

Before electrically starting up the switch, perform the following checkups after the
switch is installed:
 If S2510-B is installed on a DIN rail, check whether the installation is strong; if
S2510-B is installed on a workstation, check whether you spare enough space
for S2510-B to cool itself and whether the workstation is stable.
Figure 3- 4 RJ-45 connector of the console port
Table 3- 3 Definition of the pins of the gigabit RJ-45 port
Pin name
S2510-B Hardware Installation Manual
Symbol
TXD1+
TXD1-
RXD1+
TXD2+
TXD2-
RXD1-
RXD2+
RXD1-
Remarks
Output
Output
Input
Output
Output
Input
Input
Input