30 electrolux

Electrical Connection

The oven is designed to be connected to
230-240V~(50Hz) electricity
supply.
The oven has an easily accessible terminal
block which is marked as
follows:
Letter L
-
Live terminal
Letter N
-
Neutral terminal
E
-
Earth terminal
This oven must be earthed!
1
The cable used to connect the oven to the
electrical supply must comply to the specifi-
cations given below.
For UK use only
Connec-
Min. size
tion
Cable/
via
flex
Cooker
2,5 mm
Control Circuit
It is necessary that you install a double pole
switch between the oven and the electricity
supply (mains), with a minimum gap of 3mm
between the switch contacts and of a type
suitable for the required load in compliance
with the current regulations.
The switch must not break the yellow and
green earth cable at any point.
Important
After installation and connecting, the cable
must be placed so that it cannot at any point
reach a temperature of more than 50°C
above the ambient temperature.
Before the oven is connected, check that the
main fuse and the domestic installation can
support the load; and that the power supply
is properly earthed.
The manufacturer declines any respon-
sibility should these safety measures
not be carried out.
Cable/
flex
Fuse
type
2
PVC/PVC
min:
twin and
15A
earth
max:
20A