Maximum recommended continous cycle rate:Cycles/min 20
Maximum recommended intermittent cycle rate:Cycles/min 40
Air consumption @ 15 cycles/min and 6 bar [87 psi] air inlet
Air consumption @ 30 cycles/min and 6 bar [87 psi] air inlet
Class 3.4.2 Air Quality (Refrigerant dried - water +3ºC@7bar) may be used, however,
Note:
#
above 15 cycles/min optional heavy duty mufflers 192821 or piped exhaust system should
be used, if used continuously.
77-3233 R4.3
Specification
Maximum air inlet pressure: 7 bar [101.5 psi]
Maximum fluid pressure: 21 bar [304.5 psi]
Nominal flow volume / cycle: 0.375 l/m [0.10 US gal/m]
Output @ 60 cycles / min: 22.5 l/m [6 US gal/m]
Fluid inlet connection:
Fluid outlet connection:
Compressed Air Inlet 3/8" BSPP / NPSM
Air volume / cycle @ 3.1 bar/45psi:
Air volume / cycle @ 6.2 bar/90psi:
Max. Pump Fluid Inlet Pressure
Air Quality ISO 8573.1 Class 3.3.2
Ratio: 3:1
1" Sanitary
1" Sanitary
4.8 l/m [0.17 SCFM] @ 3.1 bar [45 psi]
9.3 l/m [0.33 SCFM] @ 90 psi [6.2 bar]
142 l/m [5 CFM]
pressure:
283 l/m [10CFM]
pressure:
2 bar [30 psi]
# See Note
Weight:
4/20
Dirt: microns
Water: -20°C @ 7bar [940ppm]
Oil: 0.1mg/m³
21 kg / 46 lbs