How To Replace The UV Light
1.
Before replacing the UV light, please unplug the unit.
2.
With the front of the unit facing up, pull up the lower end of the inlet grill and push it
toward the display panel at the top of the unit, then remove it.
3.
Remove the filter by lifting the pull string.
4.
Unscrew the screws on the lampshade with a screwdriver, and then remove
the lampshade.
5.
Gently rotate the bulb a quarter turn in either direction until it unlocks from the socket.
Pull the pins out of the sides of the socket, one end at a time.
6.
Unpack the new UV bulb gently by handling the ends only. Starting with one end of the
bulb, then the other, gently insert the metal pins on the bulb into the white slotted socket
one pin at a time. Once the ends of the bulb are completely inserted into the socket,
rotate the bulb a quarter turn until it locks into place.
7.
Reinstall the lampshade.
8.
Reinsert the filter.
9.
Hook the fasteners on the intake grid into the holes on the unit first, and then push down
on the two sides of the inlet grid until the cover snaps into place.
www.alen.com 1-800-630-2396