2 OPERATION AND FITTING INSTRUCTIONS
2.1 OPERATING CONDITIONS
The tank shall only be used in accordance with the conditions specified on the power plate
and in instructions for electric wiring. Besides legally acknowledged national regulations and
standards, also conditions for connection defined in local electric and water works have to
be adhered to, as well as the installation and operation manual. The temperature at the
place of heater installation must be higher than +2°C; and the room must not freeze. The
appliance has to be mounted at a convenient place; it means that the appliance must be
easily available for potential necessary maintenance, repair or replacement, as the case may
be.
We would like to emphasise that the heater must not be connected to power supply if
work involving flammable liquids (petrol, spot remover) or gases, etc., is performed
nearby.
If water is strongly calcareous we recommend that any of the common decalcifying devices
was installed with the appliance, or that the thermostat was set to the minimum operating
temperature of 60
adequate quality shall be used. To avoid potential sediments we recommend that the device
was installed together with a water filter.
2.2 WALL MOUNTING
Prior to mounting, check the loading capacity of the wall and, depending on the type of
masonry, choose a suitable anchorage material, or reinforce the wall, if needed. Mount the
water heater only in horizontal position so that, from the front view, the right edge of the
heater was placed at least 600 mm from the opposite wall. In combined and electric
heaters, elbows have to be attached to the hot service water inlet and outlet prior to their
suspension in brackets right under the ceiling and, by turning these elbows, mounting left
has to be determined - either from the right, or from the left. With regard to various types of
carrying masonry and broad assortment of special anchorage material available at the
market, we do not provide heaters with this material. The anchorage system has to be
selected individually, depending on the conditions (Obrázek 3). We recommend an
authorised company perform mounting on the wall and anchorage, or discuss the anchorage
with professional.
If the hot water heater is mounted in a tight, small space, or in an intermediate ceiling, etc.,
you have to make sure that the connecting side of the appliance (connections to water
supply, area for electric plugging) remained accessible and no heat accumulation occurs.
Free space of up to 600 mm from the bottom edge of the heater has to be available under
the heater.
o
C (setting to position „60").For proper operation, drinkable water of
- 9 -