Drazice OKH 100 NTR/HV Instrukcja obsługi i instalacji - Strona 3
Przeglądaj online lub pobierz pdf Instrukcja obsługi i instalacji dla Podgrzewacz wody Drazice OKH 100 NTR/HV. Drazice OKH 100 NTR/HV 12 stron. Tank type indirect water heaters
Również dla Drazice OKH 100 NTR/HV: Instrukcja obsługi i instalacji (16 strony), Instrukcja obsługi i instalacji (17 strony)
2.
MESSAGE FOR CUSTOMERS
Hot water consumption
Consumption of hot water in households depends on the number of people, amount of sanitary equipment, length,
diameter and insulation of piping in the flat, or on individual habits of users.
Energy saving
Hot utility water reservoir is insulated by means of a first-class polyurethane foam with zero freon content.
Adjust the temperature of the heater's thermostat to that level only that you need to run your home. Thus you will
reduce electricity consumption, as well as the amount of lime sediments on the walls of the receptacle and on the heat
exchanger.
Advantages of using indirect heater
- Easy installation and connection to hot water supply.
- Very fast hot water heating system
- Enamelled steel tank ensures all hygienic requirements on the quality of hot utility water.
- Built-in Mg anode increases resistance to corrosion.
- Good quality polyurethane insulation ensures minimum thermal losses.
- Continuously adjustable temperature of hot utility water| up to 74°C
- Connection of multiple withdrawal points.
- Heater operation control light.
- Accurate check of hot service water temperature.
- Possibility of connecting hot service water circulation.
3.
TECHNICAL DESCRIPTION
The heater receptacle is made of a steel plate and tested by 0.9 MPa overpressure. The inside of the receptacle is
enamelled. A flange is welded onto the upper bottom of the receptacle with a flange lid is screwed to it. A sealing ring
is inserted between the flange lid and the flange.
Thermowells for thermostat sensors and thermometer installation are placed in the flange lid. Anode rod is
mounted on M8 nut. The water reservoir is insulated by means of polyurethane foam. Electric wiring is placed
underneath the plastic removable cover. The temperature of water can be set using the thermostat.
Heat exchanger is welded in the pressure tank.
Technical description:
OKH 100 NTR, OKH 125 NTR, OKHC 160 NTR,
3