Attention! In doing so, the cold water supply pipe and the connection fitting of the tank may get
heated! If the hot water heater does not work, or if hot water is not withdrawn, no water shall
drip off the safety valve. If water drips, then the water pressure in the supply piping is either too
high (if higher than 4.8 bars, a pressure control valve has to be fitted), or the safety valve is
defective. Please call a specialized plumber immediately!
If water contains too many minerals, an expert has to come to remove the scale that forms inside
the tank, as well as free sediments. This has to be performed after one or two years of operation.
The cleaning is carried out through the hole in the flange - dismantle the flange lid and clean the
tank. A new sealing has to be used for re-fitting. Since the inside of the heater has special enamel,
which must not get in contact with the scale removing agent - do not work with a lime pump.
Remove the lime layer with a timber and suck it off, or wipe it off with a clout. After that, the
appliance must be rinsed thoroughly, and the heating process is checked the same as during the
initial putting in operation. Do not use any abrasive cleaning agents (such as liquid sand,
chemicals - acid, alkaline) or dye thinners (such as cellulose thinner, trichlor, and the like)to clean
the outer shell of the heater. For cleaning use a wet clout and add a few drops of liquid cleaning
agent for household applications. Repeated heating causes lime scale settling on the receptacle
walls and mostly on the lid of the flange. Lime scale settling depends on hardness of heated
water, its temperature and on the volume of hot water used.
We recommend checking and cleaning the tank from scale and eventual replacement of the
anode rod after two years of operation. The anode life is theoretically calculated for two years
of operation; however, it changes with water hardness and chemical composition in the place
of use. Based on such an inspection, the next term of anode rod exchange may be determined.
If the anode is only blocked with sediments clean its surface and, if used up, mount a new one.
Have a company in charge of service affairs deal with the cleaning and exchanging of the anode.
When draining water from the heater, the combination faucet valve for hot water must be open,
preventing occurrence of under-pressure in the heater tank which would stop the water from
draining.