Drazice OKHE ONE/E100 Instrukcja obsługi i instalacji - Strona 6
Przeglądaj online lub pobierz pdf Instrukcja obsługi i instalacji dla Podgrzewacz wody Drazice OKHE ONE/E100. Drazice OKHE ONE/E100 19 stron. Flat tank-type water heater for vertical mounting
1.3
DESIGN AND GENERAL HEATER DIMENSIONS
The heater tanks are made of a steel plate and tested by 1.5 multiple of operation pressure value. The inside
of the tank is enameled. A flange is welded onto the bottom of the tanks with a flange lid screwed to it. A
sealing ring is inserted between the flange lid and the flange. Thermowells for placing a heating element,
thermostat sensors and safety fuses are located in tone flange lid, and the safety fuses and the second flange
lids are without thermowells. An anode rod is mounted onto the M8 nut. Electric wiring is placed underneath
the plastic removable cover. Description of basic parts of the heater - Figure 1. Heater dimensions - Figure 2.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Service thermostat with external control and safety fuse
11. Drain tube
Enameled steel receptacle
Heater shell
Polyurethane insulation
The heating element well, ceramic heating unit 2000 W, OKHE ONE/E 30 - 1100 W
Thermostat sensor well and temperature indicator
Mg anode
Filling-in tube
Electric installation cover
Thermometer
Figure 1
- 6 -