4.
Normal dispensing
Before using the Meter it should always be reset to show 0.00 on the display by pressing the RESET button.
To start dispensing, press the "safety lock" before pressing the "trigger handle". This ensures that you won't accidentally
release oil e.g. when pulling down from a hose reel.
The "trigger handle" can be locked in the open position, and released by pressing the trigger handle once more.
5.
Pre set dispensing
Press the SELECT button, or any of the UP/DOWN arrow
buttons, to activate the PRE-SET function. PRE-SET mode
is indicated with the PRE-SET mode indicator on the display
(AUTO symbol lit up).
Pre-setting of volume is then done with the UP/DOWN arrow
buttons in increments of 0.1 liters (or quarts, pints, gallons).
Hold down a key for more than 4 seconds for the increments
to change to 1.0 liters (or quarts, pints, gallons)
for faster setting of big volumes.
To start "pre-set dispensing", proceed as when starting a
"normal dispensing" and lock the "trigger handle"
in the open position.
NOTE! When in PRE-SET mode (AUTO symbol lit up) the
dispensing must be started within 10 seconds or the meter will
return to BATCH mode.
When the pre-set volume is reached the meter will automatically
stop dispensing and an alarm will be heard.
The display will at this point switch to show the actual dispensed
volume in BATCH mode.
NOTE! Before continuing dispensing, or starting a new dispense,
the trigger handle must be pressed once to release
the pre-set mechanism.
If the dispensing is continued without resetting the display this
the already dispensed figure
A new dispensing, normal or pre-set, can now be started.
O P E N
L O C K O P E N
C L O S E
volume
L
L
L
L
10 sec
L
will be added to
4(8)