DDA-416/WC106 SPECIFICATIONS
INPUTS
CONNECTORS
LEVEL
IMPEDANCE
SAMPLE RATES
OUTPUTS
AES/EBU OUT CONNECTORS
LEVEL
IMPEDANCE
JITTER
CLOCK OUT CONNECTORS
IMPEDANCE
LOOP-THRU
INDICATORS
INPUT FAULT
INPUT TERMINATION
INPUT SAMPLE RATE
WORD LENGTH
DIGITAL ERRORS
INPUT RE-CLOCKING
MODE
INPUT EQ
SOURCE MONITOR &
CONTROL
POWER
SIZE
WEIGHT
WARRANTY
Specifications
a re
s ubject
t o
c hange
w ithout
n otice
t o
u pgrade
t he
p erformance
o f
o ur
p roducts.
13
DDA-‐416/WC106
M anual
XLR female for AES/EBU and AES Sync BNC for Word Clock
XLR 200 mVp-p minimum; BNC 1 Vp-p minimum
Transformer isolated, balanced and floating, XLR 110Ω, BNC 75 Ω;
input terminations may be switched in or out via front panel control
30kHz to 200kHz
16 x XLR male
5 Vp-p loaded at 110Ω
110Ω
< 800 picoseconds
6 x BNC
LEVEL
2 Vp-p loaded
75Ω, unbalanced
XLR-M and BNC
AES 1, AES 2, AES 3, AES 4, AES External Sync, Word Clock
Terminated or Un-terminated (OFF)
32, 44.1, 48. 88.2, 96, 176.4 or 192kHz
16 Bits, 18 Bits, 20 Bits and 24 Bits
Bi-Phase Parity, Validity, Non-Linear PCM and DTS-CD Signal
On and Off
Pro and Consumer
Locked and Enabled
AES 1, AES 2, AES 3, AES4, AES External Sync, Word Clock
Internal Supply, 115/230VAC ±10%, 47-63 Hz, IEC320 3-pin
connector
2 RU Package, 19" (48.3cm) W x 3.5" (8.9cm) H x 8.5" (21.6cm) D
9 pounds (4.1 kg) net; 10 pounds (4.5 kg) shipping weight
Limited, One Year Warranty