The top area of the menu sets the device settings. Devices are the camera or flash plugged into the
ports on the side of the unit. Device1 refers to the Camera/Flash 1 port and Device2 refers to the
Camera/Flash 2 port. The bottom area selects the sensor that is associated with a particular device.
For understanding how the menu is configured, the menu consists of four sections that work together
to configure the device and sensor setting. Each device can be triggered by either (or both) sensor.
The upper left section configures device 1, the upper right section configures device 2, the lower left
section configures sensor 1 and the lower right configures sensor 2. See the example configurations
below for more information on the configuration of this menu.
The table below shows the different settings available for each parameter and a brief description of
the function of that parameter.
Parameter
Trigger Sensor
Delay ms
Bulb sec
Prefocus
Options
Sensor1
Sensor2
S1_or_S2
S1_and_2
None
Numeric value
between 000.0 and
999.9
Numeric value
between 00 and 99
No
Description
This setting determines which sensor triggers the
device. For example, if Device1 is set with Trigger
Sensor = Sensor1 then when sensor 1 is triggered,
device 1 will fire. When S1_or_S2 is selected,
the device will fire if either sensor is triggered and
when S1_and_2 is selected, the device will fire
only if both sensors are triggered. The setting of
None will turn off triggering of that device.
This is the number of millisecond delay between
when the sensor is triggered and the device will
fire. Using the Select and Arrow buttons allows
changing one of the four numeric values at a time
until the desired delay is set.
The number of seconds that the device will be
activated.
If set to Yes, the pre-focus pin will be pulled high