Electrolux ZUCA1 Podręcznik użytkownika - Strona 6
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Zmywarka Electrolux ZUCA1. Electrolux ZUCA1 14 stron.
-
On the model with free-fall drainage:
connect the waste outlet pipe "C" (Figure 4) to the
main drain pipe, fitting a trap, or place the outlet pipe
over an S trap set into the floor.
-
On the model with drain pump:
position the outlet pipe at a height anywhere between
750 and 1000 mm from the floor.
Check that about 4 litres of water flow out of the outlet
pipe during the rinse cycle.
B2
ELECTRICAL CONNECTION
7
8
9
10
11
12
Figure 10
CAUTION:
!
THE EARTH AND ELECTRICAL CON-
NECTIONS SHOULD BE IN COMPLI-
ANCE WITH NATIONAL REGULATIONS.
•
Before carrying out the electrical connection, check
that the voltage and frequency on the appliance
rating plate correspond to those of the mains
electricity supply.
•
The earth wire at the terminal end must be longer
(max. 20 mm) than the phase wires.
•
Connect the earth wire of the power supply cable to
an efficient earth clamp. The appliance must also
be included in a unipotential system, the connec-
tion being made through the screw "Q" (Figure 4)
marked with the symbol "
must have a cross section of 10 mm
Power supply 220-230V 1N
Figure 11
Open the power supply terminal board.
Using a suitable power cable (see technical data table),
connect the phase wire to terminal L, the neutral wire to
terminal N and the earth wire to the terminal
8
1
2
3
4
5
6
. .
0 . .
4 0
A C
". The unipotential wire
2
.
.
Three-phase version:
Power supply 400...415V 3N
L1
L2
L3
Figure 12
Open the power supply terminal board and insert the
jumpers provided as follows: one jumper between termi-
nals 2 and 4 and another between terminals 4 and 6.
Using a suitable power supply cable (see technical data
table), connect the three phases to terminals 1, 3 and 5,
the neutral to terminal 4 and the earth wire to the termi-
nal
.
Power supply 220-230V 3
L1
L2
L3
Figure 13
Open the power supply terminal board and insert the
jumpers provided as follows: one jumper between termi-
nals 1 and 2, one between terminals 3 and 4 and
another between terminals 5 and 6. Using a suitable
power supply cable (see technical data table), connect
the three phases to terminals 1, 3 and 5 and the earth
wire to the terminal
.
Power supply 220-230V 1N
Figure 14
Open the power supply terminal board and insert the
jumpers provided as follows: two jumpers between ter-
minals 1, 3, 5 and another two between terminals 2, 4
and 6.
Using a suitable power supply cable (see technical data
table), connect the phase and neutral to terminals 5 and
6 respectively and the earth wire to the terminal
.