MINIMUM WIRE DIMENSIONS & FUSE SIZES
WINCH
WIRE LENGTH*
0-3 m / 0-10 ft
28 STE SE
3-8 m / 10-27 ft
0-3 m / 0-10 ft
40 STE SE
3-8 m / 10-27 ft
0-3 m / 0-10 ft
46 STE SE
3-8 m / 10-27 ft
0-3 m / 0-10 ft
52 STE SE
3-8 m / 10-27 ft
*) WIRE LENGTH is defined as the distance from battery to switch box + the distance from switch box
to motor.
IMPORTANT: Fuse must be of a slow blow type.
www.Busse-Yachtshop.de - [email protected]
(Not for continuous service)
WIRE
35 mm²
50 mm²
35 mm²
50 mm²
50 mm²
70 mm²
50 mm²
70 mm²
For current World Wide Distributor list please see:
www.andersenwinches.com
12V. DC
FUSE
BAT.
CAP.
125 A
240 Ah
160 A
240 Ah
125 A
240 Ah
160 A
240 Ah
160 A
360 Ah
200 A
360 Ah
160 A
360 Ah
200 A
360 Ah
24V. DC
WIRE
FUSE
BAT.
CAP.
25mm²
76 A
120Ah
25mm²
100 A
120Ah
25mm²
76 A
120Ah
25mm²
100 A
120Ah
25mm²
100 A
180Ah
35mm²
125 A
180Ah
25mm²
100 A
180Ah
35mm²
125 A
180Ah