this function is active. The counter will check the ultra-violet feature of the
counted banknotes.
3. Magnetism function
Press the CF button, when the MG symbol on display is light on, which means
this function is active. The counter will check the magnetic ink of the counted
banknotes.
4. Banknote Width Detection
The machine will stop and beep if it encounters a shorter banknote in the
batch of same size banknotes, and "EE4" code will be displayed. The
suspicious banknote is the top banknotes in the banknote stacker.

Feeder Adjustment

The adjusting screw of the feeder aperture on the back cover has alre-
-ady been set at the factory. You may need to adjust the feeder aperture if
the following problems occur during counting:
Frequent jams, or banknotes pass the feeder
with difficulty - turn the adjusting screw counter-
clockwise to make the aperture wider.
Frequent "EE5" or "EEA" error message
turn the adjusting screw clockwise to make the
aperture smaller.
The adjusting screw is very sensitive, move only one notch at a time!
6
loosen
Tighten
Wider the aperture Smaller the aperture
CARNATION
Note! When "EE7" code is displayed, the
banknotes have not been placed in the
hopper properly. Please redo it.

Parts Replacement

1.The resistance piece needs to be replaced
when worn. Pull out the banknote feeder,
press the banknote sliding board down,
and replace the worn resistance piece.
2. In case machine doesn't turn on, check the
fuse. The fuse cover is located under the
power cable socket.

Maintenance

1.If operated at temperature below 68℉(20℃), please allow three minutes for
warm-up.
2.The machine must be operated in a well-ventilated area. Keep it away from
direct sunlight and strong magnetic fields.
3.Do not apply oil to machines rubber parts, as it may cause malfunction.
4.Clean all sensors and magnetic head with brush at least once a week.