Bosch AXXIS WTL 5410 Instrukcja obsługi i konserwacji - Strona 13
Przeglądaj online lub pobierz pdf Instrukcja obsługi i konserwacji dla Suszarka Bosch AXXIS WTL 5410. Bosch AXXIS WTL 5410 24 stron. Electric vented/condensation dryer
SELF-HELP
Dryers may exhibit problems that are unrelated to a malfunction of the dryer itself. The following table may serve to
answer your question about a problem you are having without having to call a serviceman.
PROBLEM
''On/Off'' Indicator light does not
come on
Dryer does not start
Cycle is interrupted and ''Lint
Filter'' light is illuminated and
buzzer sounds
Cycle is interrupted, buzzer
sounds, one or several cycle
indicators are flashing
Drying level not reached or
drying time too long
The laundry is not dry even
though the highest drying level
has been selected
Drum light does not work
Following items apply only to the WTL (Condensation Electric Dryer) models
Cycle is interrupted and ''E1''
appears in display
Humidity level in room
increases greatly
Table 2.
POSSIBLE CAUSE
l
The ''On/Off'' has not been depressed.
l
A fuse may have blown or a circuit breaker tripped. Replace fuse or reset circuit
breaker at your fuse box/breaker box.
l
The plug is not correctly or only loosely inserted into the receptacle.
l
Cycle has not been selected.
l
'Start'' button has not been depressed.
l
Door is not closed properly.
l
Room temperature is below 32 F (0 C)
l
If necessary, switch the machine off and wait 5 seconds before switching it on
again. Select the cycle again and depress 'Start''.
l
Clean Lint Filter as described in section titled CARE and CLEANING.
l
(WTA models) Check exhaust vent to see if it is blocked or too long.
l
(WTL models) Clean heat exchanger as described in section titled CARE
and CLEANING.
l
(WTL models) Check air inlet to make sure it is not blocked.
l
Indicates faulty operation:
–
Clean the Lint Filter, check the exhaust duct length (WTA models),
–
Switch the dryer off, wait for it to cool down and then restart.
l
Clean the Moisture sensors in the drum as described in section titled CARE and
CLEANING.
l
If there is a power failure for an extended period the cycle must be restarted.
l
The drum is too full.
l
The laundry was too wet when placed in the dryer.
l
The room is not adequately ventilated. Make sure there is an adequate supply of
fresh air.
l
The lint filter is blocked and should be cleaned.
l
(WTA models) The exhaust vent is blocked or too long.
l
(WTL models) The air inlet is blocked.
l
''On/Off'' button has not been pressed.
l
Bulb has failed. For safety reasons the bulb must only be replaced by an
authorized service agent.
l
Condensate hose is blocked in some way. Turn off dryer and check hose.
l
The room is not adequately ventilated. Make sure there is an adequate supply of
fresh air.
l
Check air inlet to see if it is blocked.
l
The heat exchanger was removed but not replaced.
13