Community IC6-1082/96 Instrukcja instalacji i obsługi - Strona 9

Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Głośniki Community IC6-1082/96. Community IC6-1082/96 16 stron. I series

Community IC6-1082/96 Instrukcja instalacji i obsługi
RIGGING SAFETY
IMPORTANT: The loudspeakers described in this manual are designed
and intended to be mounted to differing building surfaces using a
variety of rigging hardware, means and methods. Installation of loudspeakers
should only be performed by trained and qualified personnel. It is strongly
recommended that a licensed and certified professional structural engineer
approve the mounting plan. Severe injury and/or loss of life, and property
damage may occur if these products are improperly installed.
DANGER: All rigging fittings must be fully tightened and secured. Any
missing fasteners will compromise the structural integrity of the
enclosure and constitute a safety hazard. Do not suspend any loudspeakers
unless all fasteners are securely in place!
ACCEPTABLE MOUNTING POINT LOADING
The mounting points should always be used so that either shear force is applied
perpendicular to the direction of and in tight proximity to the mounting hole, or
tension force is applied perpendicular to the enclosure surface.
DANGER: Use the mounting points only as described above. Do not use
them in such a way as to apply sideways leverage to them. Failure to
follow this instruction could result in failure of the mounting points resulting in
damage to the loudspeaker and serious injury or death to personnel.
IC6-1062
Figure 5. Shown with optional U-Brackets
IMPORTANT: The flat-head hex-drive rigging screws that come installed in
each enclosure must either be replaced with rigging brackets and threaded
fasteners, or they must be kept in place to seal the enclosure from air leaks. If
the rigging fittings do not remain sealed, air leaks will occur in the enclosure that will
compromise the low-frequency performance with distortion, reduced output, and
premature driver failure.
I SERIES Compact 600
IC6-2082
Quick Start Guide
Figure 4. Possible safety cable mounting
point with an eyebolt (not included)
ATTACH SAFETY CABLE
Attach a safety cable to one of
the unused mounting points.
The safety cable and hardware
are not included. Please consult
a structural engineer for the
appropriate cable and hardware
for the load and application. The
safety cable must be secured
to a suitable load-bearing point
separate from the loudspeaker
mounting point, with as little
slack as possible, so as not to
develop undue kinetic force if the
loudspeaker mount were to fail
(see Figure 4 above).
The U-Brackets and Vertical Yokes
have hole patterns compatible with
BalancePoint™
Flyware
frames, and are also compatible with
many
third
party
speaker stand adapter plates, ceiling
or pole mount brackets and wall mount
arms. Refer to our reference table or
manufacturer's website for details.
IMPORTANT: I SERIES Compact
rigging fittings are designed to
support the load of the cabinet
using Community supplied or third party
manufactured
mounting
Additional cabinets should NOT be
suspended from any mounting point.
rails
and
manufacturers'
brackets.
Page 9