Anderson VFS82 Instrukcja obsługi - Strona 6

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Palnik Anderson VFS82. Anderson VFS82 16 stron.

5.3 Ignition Burner

VFS82 Series Burner has a separated ignition burner of maximum capacity 50kw. User need
to supply fresh combustion air for ignition pilot, so, a small air blower or compressed air
needs to be applied to the pilot burner. According to pilot burner's manual, 5mbar
combustion air and 3mbar gas pressure are necessary for pilot burner operation. The
pressure above is needed for neutral environment, if oven chamber pressure is not neutral,
chamber pressure needs to be added to the pressure value above. It should be noted that
the depth of ignition burner extend to main burner is adjustable according to site
requirement. Pilot burner diagram shown as Fig. 2 as blew.

6. VFS82 Burner Operation Data

VFS82 series burners operation datasheet shown as Table 1:
PARAMETER
Maximum Input (MW)
Minimum Input(MW)
Gas Inlet Pressure(mbar)
Combustion Air
Pressure(mbar)
Anderson Thermal Soluions(Suzhou)Co., Ltd
Anderson Thermal Solutions – VFS82 Burner Operation Manual
Fig. 2 Pilot burner
Table 1: VFS82 Series Burners Operation Datasheet
VFS82G 30 VFS82G 50 VFS82G 65 VFS82G 95 VFS82G 120 VFS82G 160
3
5
0.1
0.2
60
60
20
20
BURNER TYPE
6.5
9.5
0.3
0.4
60
60
20
20
4
12
16
0.4
0.6
60
115
20
20