Guideline for sealing the gasket with silicone in step 4-13
The silicone is necessary to seal the cable entrance points. This work
requires very exact and accurate work, because the cable entrance
section is the most sensitive part of the system.
• General rule: More is better than less.
• Too much silicone has to be removed afterwards, but is harmless.
• Please use the silicone tubes only once. The silicone has the tendency
to dry out and may not work properly the next time. Enough tubes are
supplied.
Take the silicone tube, twist of the cap, open the tube with the cap and
mount the nozzle. Hold the tube upright and roll up the tube from the bottom
until silicon appears on top of the nozzle.
Apply the
silicone
cable entrance section as shown
bottom of the cable entrance section should now be covered with a flat layer
of silicone. The silicone has to reach the gasket groove at both sides and
must not have any gaps.
Put the cap of the tube on top of the nozzle to avoid the silicon to drying up
during the time of your work.
Instruction Manual CYPRES Water Resistant Kit
4.
(length apx. 3cm, minimum width approx. 8mm) to the
(blue
Airtec GmbH
section) on the photo. The complete
page 6