Caroma Invisi Series II Instrukcja instalacji - Strona 18

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Produkt hydrauliczny Caroma Invisi Series II. Caroma Invisi Series II 20 stron. Urinal concealed cistern
Również dla Caroma Invisi Series II: Podręcznik (16 strony)

Caroma Invisi Series II Instrukcja instalacji
Servicing Requirements
Troubleshooting Guide
Spare Parts Information
Maintenance & Spare Parts Instructions
1
Ensure mains water is turned off and
remove Inlet Valve from cistern as per the
instructions on page 17.
3
Seal
Remove seal from Cap Assembly.
18
Inlet Valve Seal may require periodic cleaning (dependant on water quality).
- procedure as defined below.
Inlet Valve is slow to fill OR fails to open ► Ensure tap is open.
Inlet Valve fails to close ► Clean & inspect seal as described above, replace Cap Assembly
If any other issues arise ► Consult a plumber or Caroma After Sales Service.
Caroma Invisi II Inlet Valve compatible Spare Part Kits are:
687 171 Containing - 1 x Complete Unifill Inlet Valve
687 049 Containing - 1 x Cap Assembly
Refer to
- Maintenance & Spare Parts Instructions
2a
Bracket
To replace complete Inlet Valve:
rotate nut & pull to disconnect it from the
Bracket.
4
Wash seal to remove any dirt and inspect
for damage.
& Seal if damaged.
with bayonet connection
- 1 x Seal
Inlet
A
Valve

Servicing - Inlet Valve

Cap Assembly
Seal
2b
B
To clean and inspect seal:
unclip the Adjustment Screw, rotate & pull
to remove cap assembly.
5
C
Helplines
A
Replace seal onto cap assembly.
If necessary replace cap & Seal (Spare Part
Kit 687 049)
Push & rotate to re-attach cap assembly,
re-clip Adjustment Screw and refit into
cistern.
C
Cap
Assembly
A
Adjustment
Screw
B
D