Comnet FVR20C2S2 Instrukcja instalacji i obsługi - Strona 5
Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Odbiornik Comnet FVR20C2S2. Comnet FVR20C2S2 5 stron. Single, dual or quad-channel 10-bit digitally encoded short-haul video and contact closure
Również dla Comnet FVR20C2S2: Instrukcja instalacji i obsługi (8 strony)
INSTALLATION AND OPERATION MANUAL
FIGURE 7 – LED INDICATORS
LINK
GREEN
Communication link has been
established over optical fiber
RED
Communication link has not
been established.
OFF
Unit powered down.
* Contact Closure channels are not operational when used with the FVT1(M,S)1/M transmitters.
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units should
be installed in dry locations protected from extremes of temperature and
humidity.
C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that the
power supply be turned off and that the rack power supply is disconnected
from any power source. Note: Remove electrical connector before
installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the
card guides in the rack until the edge connector at the back of the card
seats in the corresponding slot in the rack's connector panel. Seating
may require thumb pressure on the top and bottom of the card's front
panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the
card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 power supply.
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multi-
unit rack assembly, the operating ambient temperature of the
rack environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature
(Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should
be such that the amount of air flow required for safe operation of the
equipment is not compromised.
© 2013 Communications Networks Corporation. All Rights Reserved. "ComNet" and the "ComNet Logo" are registered trademarks of Communication Networks, LLC.
VIDEO
Video signal is present on the
channel.
Video signal is not present on the
channel.
Unit powered down.
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA
T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | [email protected]
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE
T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | [email protected]
FVR10C1(M,S)1, FVR20C2(M,S)2 & FVR40C4(M,S)4
CONTACT*
Contact input is closed.
–
Contact input is open.
FIGURE A
Dimensions are for a standard ComNet™ one slot module
INS_FVR(1,2,4)0C(1,2,4)(M,S)(1,2,4)_REV- Rev. 07.30.13 PAGE 5
.156 [3.96 mm]
.313 [7.95 mm]