4. With a thin screwdriver, adjust the
bypass screw position (A).
A
5. Reassemble the gasket and the
knob.
WARNING!
Make sure the flame does
not go out when you quickly
turn the knob from the
maximum position to the
minimum position.
3.4 Electrical connection
• Make sure that the rated voltage and
type of power on the rating plate
agree with the voltage and the power
of the local power supply.
• This appliance is supplied with a
mains cable and a plug.
• Always use a correctly installed
shockproof socket.
• Make sure that there is an access to
the mains plug after the installation.
• Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
• There is a risk of fire when the
appliance is in connection with an
extension cable, an adapter or a
multiple connection. Make sure that
the ground connection agrees with the
standards and regulations.
• Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect
the blue neutral cable to the
terminal with a letter "N" on
it. Connect the brown (or
black) phase cable to the
terminal which has a letter
"L". Keep the phase cable
connected at all times.
3.5 Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H05V2V2-F T90.
Make sure that the cable section is
applicable to the voltage and the working
temperature. The yellow / green earth
wire must be approximately 2 cm longer
than the brown (or black) phase wire.
ENGLISH