(screw type fuses removed from the
holder), earth leakage trips and contac-
tors.
• The connection cable parts must not be
heated to a temperature above 90°C.
Electrical Requirements
Permanent electrical installation must com-
ply with the latest I.E.E. Regulations and lo-
cal Electricity Board regulations. For your
own safety the installation must be done by
a qualified electrician (e.g. your local Elec-
tricity Board, or a contractor who is on the
roll of the National Inspection Council for
Electrical Installation Contracting [NICEIC]).
The manufacturer declines any liability
if these safety measures are not ob-
served.
The appliance must be connected to a 230
V 50 Hz AC electrical supply.
Before activating the appliance, make sure
the electrical supply voltage is the same as
that indicated on the rating plate. The rat-
ing plate is located on the bottom of the
appliance.
The appliance is supplied with a 3 core
flexible supply cord with a 3 amp plug. If it
is necessary to change the fuse, use a 3
amp ASTA-approved (BS 1362) fuse.
E
A)
Green and Yellow
B)
3 amp fuse
C)
Brown
D)
Cord clamp
E)
Blue
Should the plug need to be replaced for
any reason, the wires in the mains lead are
coloured in accordance with the following
code:
A
B
Green and yellow
Blue
Brown
1.
Connect the green and yellow (earth)
wire to the terminal in the plug which is
marked with the letter 'E' or the earth
symbol
low.
2.
Connect the blue (neutral) wire to the
terminal in the plug which is marked
with the letter 'N' or coloured black.
3.
Connect the brown (live) wire to the
terminal in the plug which is marked
with the letter 'L' or coloured red.
There must be no cut or stray strands of
wire present. The cord clamp must be cor-
rectly attached on the outer sheath.
WARNING!
Make sure that the cut off plug is
disposed of safely. A cut off plug
put into a 13 amp socket is a safe-
ty hazard. There is a risk of electri-
cal shock.
The replacement of the electrical
cable must be done by a qualified
electrician or competent person,
according to the current regula-
tions.
7.6 Replacement of the
connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
C
The yellow/green earth wire must be ap-
D
proximately 2 cm longer than the brown (or
black) phase wire.
7.7 Building In
min. 55 mm
480 mm
- Earth
- Neutral
- Live
, or coloured green and yel-
min. 600 mm
min. 150 mm
min. 650 mm
30 mm
560 mm