Glass & Stainless Canopy Hood
RH42PC60G S
PRE-INSTALLATION CALCULATIONS
K
Counter Height
36" standard
Top
Wiring box
42" Glass & Stainless Canopy Island Hood Specifications
Product Weight – 87 Lbs.
•
Island / Peninsula Installation
•
Ventilation is convertible to be either ducted outside, or recirculated
•
inside requiring no ducting.
Sones Rating – 9.0
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 0.516 kW (For use on
•
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 4.16 Amps
•
Always consult local and /or national electric codes. Check local
•
building codes for installation requirements, as they may vary per locale.
Minimum installation height allowed from bottom of hood to cooking
•
surface is 24" - 30" for electric and 30" for gas. (NOT more than 36"
recommended.)
To prepare mounting surface, adequate structure and support must be
•
provided, capable of supporting 150 lbs.
Ducted Option Specifications
For outside ventilation only.
•
Exhaust Duct Required – 8" round
•
For most efficient airflow exhaust, use a straight run or as few elbows
•
as possible.
Use metallic flex ducting only to connect rigid duct directly to transitions
•
(if allowed by code).
250 Bobby Jones Expressway
USA
•
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
•
•
RH42PC60G 02/08
K = Kitchen height
C = Counter height
S H
P = Preferred height
of hood bottom
above counter
A
(24"- 30"
allowed, NOT
more than 36"
P
recommended)
A = Canopy height
H = Hood height for
installation
H = K-C-P
C
S = Chimney
structure height
for installation
S = H-A
2
11
/
"
16
41
7
Air outlet -
7
7
/
" diam.
8
Controls
Augusta, GA 30907
1-877 -4electrolux (1-877 -435-3287)
•
•
1-800-265-8352
•
© 2008 Electrolux Major Appliances, NA
1
12
/
"
8
/
"
8
Thermal breaks such as short section of nonmetallic duct, should
•
be used in areas of extreme cold.
Cold weather installations should have additional backdraft damper
•
installed.
Refer to web for detailed duct preparation installation instructions.
•
Ductless (Recirculated) Option Specifications
If ducting to outside is not an option, vent hood can be converted to
•
ductless with use of optional Duct-Free Kit (RHDFP60GS).
Refer to web for detailed convertible ventilation installation instructions.
•
Pre-Installation Calculations
Select hood preference height (P) that is comfortable for user
•
(24" - 30" minimum allowed, NOT more than 36" recommended).
Calculate hood height (H) for installation (H = K-C-P).
•
Confirm that (H) is within minimum to maximum range for hood.
•
If not, adjust installation.
Calculate chimney structure height (S). Use formulas, check
•
dimensions of hood. Save calculation for use later in installation.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
Duct-Free Kit – (RHDFP60GS).
•
electroluxappliances.com
•
electroluxappliances.ca
•
13
3
/
"
16
Dimensions
from base of
hood to ceiling,
and include
clearance
required for
28"
installation.
( min.
height
with one
cover)
25
3
/
"
16
High standards of quality at Electrolux Major Appliances mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
35"
min.
57"
max.
Printed in the U.S.A.